Heavy-Load Torque During Deceleration in the Forward Direction
Program  Special  Crane/Hoist Load
During forward deceleration, this parameter establishes the threshold
torque level that is used to determine if the Light-Load High-Speed
(F331) operation may engage or remain engaged if active.
If the Light-Load High-Speed operation is terminated normal operation
resumes.
Switching Load Torque During Reverse Run
Program  Special  Crane/Hoist Load
While running in reverse, this parameter establishes the threshold torque
level that is used to determine if the Light-Load High-Speed (F331)
operation may engage or remain engaged if active.
If the Light-Load High-Speed operation is terminated normal operation
resumes.
Heavy-Load Torque During Acceleration in the Reverse Direction
Program  Special  Crane/Hoist Load
During reverse acceleration, this parameter establishes the threshold
torque level that is used to determine if the Light-Load High-Speed
(F331) operation may engage or remain engaged if active.
If the Light-Load High-Speed operation is terminated normal operation
resumes.
Heavy-Load Torque During Deceleration in the Reverse Direction
Program  Special  Crane/Hoist Load
During reverse deceleration, this parameter establishes the threshold
torque level that is used to determine if the Light-Load High-Speed
(F331) operation may engage or remain engaged if active.
If the Light-Load High-Speed operation is terminated normal operation
resumes.
Frequency for Automatic High-Speed Operation at Light-Load
Program  Special  Crane/Hoist Load
This parameter establishes the speed that the ASD will ramp to when
operating in the Light-Load High-Speed mode.
https://www.toshiba.com/tic/
Direct Access Parameter Information
W7B ASD Installation & Operation Manual
Direct Access Number — F337
Parameter Type — Numerical
Factory Default — 100
Changeable During Run — Yes
Minimum — 0
Maximum — 250
Units — %
Direct Access Number — F338
Parameter Type — Numerical
Factory Default — 50
Changeable During Run — Yes
Minimum — 0
Maximum — 250
Units — %
Direct Access Number — F339
Parameter Type — Numerical
Factory Default — (ASD-Dependent)
Changeable During Run — Yes
Minimum — 0
Maximum — 250
Units — %
Direct Access Number — F340
Parameter Type — Numerical
Factory Default — 100
Changeable During Run — Yes
Minimum — 0
Maximum — 250
Units — %
Direct Access Number — F341
Parameter Type — Numerical
Factory Default — 80
Changeable During Run — Yes
Minimum — 0.00
Maximum — Max. Freq. (F011)
Units — %
F337-F341
115