Toshiba W7 DN-57442-006 Installation & Operation Manual page 116

Adjustable speed drives
Table of Contents

Advertisement

F300-F300
Direct Access Parameter Information
W7B ASD Installation & Operation Manual
PWM Carrier Frequency
Program  Special  Carrier Frequency
This parameter sets the frequency of the pulse width modulation signal
applied to the motor.
Note:
The maximum Carrier Frequency setting allowed is 5.0 kHz for
the following ASDs:
460 Volt  200 HP – 800 HP.
575 Volt  150 HP – 400 HP.
The maximum Carrier Frequency setting allowed for all other ASDs is 15
kHz.
Setting the Carrier Frequency above the Derate Threshold frequency (as
listed below) for a given ASD will reduce the capability of the ASD.
Carrier-Frequency Derate Threshold Frequency
Derate
Model
Threshold
Voltage
HP
Frequency
20
25
8.0 kHz
30
40
50
5.0 kHz
60
4.0 kHz
75
8.0 kHz
100
125
460 V
5.0 kHz
150
200
250
300
400
2.2 kHz
500
600
700
800
106
Derate
Model
Threshold
Voltage
HP
Frequency
100
125
150
175
575 V
2.2 kHz
200
250
300
400
Direct Access Number — F300
Parameter Type — Numerical
Factory Default — (ASD-Dependent)
Changeable During Run — No
Minimum — 0.500
Maximum — (ASD-Dependent)
Units — kHz
Example
0
ASD
Output
After
Derate
(%)
67
100
2.2
8
Carrier Frequency (kHz)
https://www.toshiba.com/tic/
15

Advertisement

Table of Contents
loading

Table of Contents