6. DISPLAY AND OPERATION

6.5 Parameter mode

The parameters whose abbreviations are marked* are made valid by changing the setting and then switching
power off once and switching it on again. Refer to section 5.1.2.
(1) Operation example
The following example shows the operation procedure performed after power-on to change the control
mode (parameter No.0) to the Internal speed control mode.
Using the "MODE" button, show the basic parameter screen.
www.DataSheet4U.com
To shift to the next parameter, press the
When changing the parameter No.0 setting, change its set value, then switch power off once and switch it
on again to make the new value valid.
(2) Expansion parameters
To use the expansion parameters, change the setting of parameter No.19 (parameter write disable).
Refer to section 5.1.1.
The parameter number is displayed.
Press
or
to change the number.
UP
DOWN
Press SET twice.
The set value of the specified parameter number flickers.
Press UP once.
During flickering, the set value can be changed.
Use
or
.
UP
DOWN
(
2: Internal speed control mode)
Press SET to enter.
/
button.
UP DOWN
6 - 7