5. PARAMETERS
Class
No. Symbol
40
41
www.DataSheet4U.com
42
For manufacturer setting
Do not change this value by any means.
*DIA
Input signal automatic ON selection
Used to set automatic servo-on (SON) forward rotation stroke end
(LSP) reverse rotation stroke end (LSN).
0
Servo-on (SON) input selection
Forward rotation stroke end (LSP)
input selection
0: Switched on/off by external input.
1: Switched on automatically in servo
amplifier.
(No need of external wiring)
Reverse rotation stroke end (LSN)
input selection
0: Switched on/off by external input.
1: Switched on automatically in servo
amplifier.
(No need of external wiring)
*DI1
Input signal selection 1
Used to assign the control mode changing signal input pins and to set the
clear (CR).
0 0
Control change (LOP) input pin assignment
Used to set the control mode change signal
input connector pins. Note that this parameter is
made valid when parameter No.0 is set to
select the position/internal speed change mode.
Set value
0
1
2
3
4
If forward rotation stroke end (LSP) or reverse
rotation stroke end (LSN) is assigned to any pin
with parameter No.48, this setting is invalid.
Clear (CR) selection
0: Droop pulses are cleared on the leading edge.
1: While turning on, droop pulses are always
cleared.
Name and function
0: Switched on/off by external input.
1: Switched on automatically in servo
amplifier.
(No need of external wiring)
Connector pin No.
CN1-4
CN1-3
CN1-5
CN1-6
CN1-7
5 - 14
Initial
Setting
Control
Unit
value
range
mode
0
0000
Refer to
P S
name
and
function
column.
P S
0002
Refer to
name
and
function
column.
P/S
P