Mitsubishi Electric EZMOTION MR-E Super MR-E-10A-QW003 Instruction Manual page 95

General-purpose ac servo
Table of Contents

Advertisement

5. PARAMETERS
Class No. Symbol
18
*DMD
www.DataSheet4U.com
19
Status display selection
Used to select the status display shown at power-on.
0 0
Selection of status display at
power-on
0: Cumulative feedback pulses
1: Servo motor speed
2: Droop pulses
3: Cumulative command pulses
4: Command pulse frequency
7: Regenerative load ratio
8: Effective load ratio
9: Peak load ratio
A: Instantaneous torque
B: Within one-revolution position low
C: Within one-revolution position high
D: Load inertia moment ratio
E: Bus voltage
Status display at power-on in
corresponding control mode
0: Depends on the control mode.
Control mode
Position
Position/
internal speed
Internal speed
1: Depends on the first digit setting of this parameter.
*BLK
Parameter write inhibit
Used to select the reference and write ranges of the parameters.
Operation can be performed for the parameters marked
Set
Operation
value
0000
Reference
(Initial
Write
value)
Reference
000A
Write
Reference
000B
Write
Reference
000C
Write
Reference
000E
Write
Reference
100B
Write
Reference
100C
Write
Reference
100E
Write
Name and function
Status display at power-on
Cumulative feedback pulses
Cumulative feedback pulses/
servo motor speed
Servo motor speed
.
Basic
Expansion
parameters
parameters 1
parameters 2
No.0 to 19
No.20 to 49
No.19 only
No.19 only
No.19 only
No.19 only
No.19 only
5 - 10
Initial
Unit
value
0000
0000
Expansion
No.50 to 84
Setting
Control
range
mode
Refer to
P S
name
and
function
column.
Refer to
P S
name
and
function
column.

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents