To Datafill Table Mpclink - Nortel T1/SMDI Configuration Manual

Table of Contents

Advertisement

Configuring the switch

To datafill table MPCLINK

1 Type table mpclink and press Enter.
2 Type add and press Enter.
3 Respond as shown in the following table:
Field
Subfield
LINKKEY
MPCNO
LINKNO
LINKALM
PROTOCOL
LINKNABL
62
Entry
Explanation and action
See the
This key field is composed of subfields
explanation.
MPCNO and LINKNO.
0-255
Enter the MPC number used for SMDI
(the same number entered in table
MPC).
2, 3
Enter the MPC link number for SMDI
application with ASYNC protocol.
Y or N
Enter Y to activate the MPCLINK alarm
for system busy (SYSB) MPC links.
Enter N if you do not want to activate
the MPCLINK alarm for system busy
(SYSB) MPC links.
Note: If you enter N, the system does
not generate MPC908 (MPC link state
transition) logs.
ASYNC
Enter the Link protocol. ASYNC is the
proper entry for CallPilot.
0-32 765
For a link that is not fully active, this is
the time-out in minutes before the
system goes to system busy (SBSY) and
then returns to service. Enter the
number of minutes for this time-out
(must be a multiple of five).
Standard 1.13
CallPilot