To Disable Message Transfer On The Link (For The1X89 Mpc Port Option On The Iom) - Nortel T1/SMDI Configuration Manual

Table of Contents

Advertisement

February 2008
b. MTC
c. IOD
d. IOC c (where c is the circuit number, for example, 0)
e. PORT n (where n is the port number, for example, 5)
f. RTS LINK p (where p is the link number; this is always 3)
3 Once the data link has been set up, the UCD lines (agents) must be put
into service. Enter the following commands for each agent:
a. MAPCI
b. MTC
c. LNS
d. LTP
e. 2D dn (where dn is the UCD agent's DN)
f. RTS
To disable message transfer on the link (for the1X89
MPC port option on the IOM)
To shut down message transfer on the link, enter the following commands:
1 MAPCI
2 MTC
3 IOD
4 IOC c (where c is the circuit number, for example, 0)
5 PORT n (where n is the port number, for example, 5)
6 BSY n [FORCE] (where n is the card number, for example, 5; and
FORCE is an optional parameter that you can use if the link is currently
in use and you must immediately shut down the link)
T1/SMDI and CallPilot Server Configuration
Configuring the switch
97