Directed XPRESSSTART ONE Installation Manual page 18

4x10/5x10
Hide thumbs Also See for XPRESSSTART ONE:
Table of Contents

Advertisement

Menu
Feature
Item
Timer Mode Start Inter-
10
val (Hours)
SmartStart High Tem-
11
perature Threshold
SmartStart Low Tempera-
12
ture Threshold
SmartStart Low Battery
13
Threshold (Volts)
Virtual Tach Fine Tune
14
(Milliseconds)
15
Remote Start SafeLock
Note: Features can only be programmed via the web tool. See "Connecting the module" on page 9 for more
information.
1
Engine Checking Mode
2
Cranking Time (seconds)
3
Activation Pulse Count
4
Diesel Delay Type/
Duration
5
Accessory Output During
Diesel Start Delay
6
Turbo Mode Runtime
7
Remote Start Runtime
(minutes)
8
SmartStart/Timer Mode
Runtime (minutes
9
SmartStart/Timer Mode
Start Count
10
Timer Mode Start Interval
(Hours)
11
SmartStart High Tempera-
ture Threshold
12
SmartStart Low Tempera-
ture Threshold
13
Smart Start Low battery
(Volts)
18
Opt. 1
Opt. 2
Options: 1/2/3/4 to 24 in 2 hour increments. The default value is 24 hours.
Options: +40 F to +130 F in 10 degree increments. The default value is OFF.
Options: -20 F to +70 F in 10 degree increments. The default value is OFF.
Options: 9.0V to 12.5V in 0.5V increments. The default value is 11.0V.
Not Initialized
50mS - 1000mS
Off
Safe Lock On
1.
Virtual Tach: battery voltage drop/rise during cranking determines when the starter output is re-
leased. During runtime, constant voltage level is monitored to determine if the engine is running.
2.
Voltage: starter output during cranking is a programmed duration (Set in Cranking Time). During run-
time, constant voltage level is monitored to determine if the engine is running.
3.
Off: starter output during cranking is a programmed duration (Set in Cranking Time). The remote
starter will keep the ignition/accessories active for the programmed runtime whether the engine is
running or not.
4.
Tachometer: tachometer input signal during cranking and runtime to determine when the starter output
is released and if the engine is running.
0.6/0.8/1.0/1.2/1.4/1.6/1.8/2.0/4.0 seconds: determines the starter output duration during crank-
ing for the 'Voltage' and the 'Off' Engine Checking Mode options. The default value is 0.6.
1/ 2 pulses: sets the number of remote control commands received or Activation Input required to enable
and disable remote start. The default value is 1.
1.
Wait for Glowplug input: (-) input on the Blue/Red (CN2/2) WTS wire will delay the starter output
until the input ceases.
2.
Timed 15/30/45 seconds: delays the starter output corresponding to the selected option, the WTS
wire does not function.
1.
On: Accessory output will be ON during diesel-start delay.
2.
Off: output will be OFF during diesel-start delay.
1.
0 – Turbo Mode disable: turbo mode is NOT available.
2.
1 to 10 minutes – On: turbo mode is available and, when activated, the engine will run for the dura-
tion set according to the selected option. The default value is 3 minutes.
1 to 60 minutes: sets engine runtime during normal remote start operations. The default value is 12 minutes.
1 to 16 minutes: sets the runtime when the engine is started by the Timer Mode and SmartStart features.
The default value is 3 minutes.
1/2/3/4 to 24 (Starts) in increments of 2: sets the number of times the engine will be started by the Timer
Mode and SmartStart features. The default value is 1 start.
1/2/3/4 to 24 in 2 hour increments: sets the number of hours between engine starts by the Timer Mode
and SmartStart features. The default value is 24 hours.
+40 F to +130 F in 10 degree increments: sets the high temperature threshold required for SmartStart to
turn the engine on. The default value is OFF.
-20 F to +70 F in 10 degree increments: sets the low temperature threshold required for SmartStart to turn
the engine on. The default value is OFF.
OFF, 9V to 12.5V in 0.5V increments: sets the low battery level threshold required for SmartStart to turn the
engine on. The default value is 11.0V.
Opt. 3
Opt. 4
Smart Safe Lock
On
Opt. 5+
XpressStart ONE 4x10/5x10 Analog