Directed XPRESSSTART ONE Installation Manual page 20

4x10/5x10
Hide thumbs Also See for XPRESSSTART ONE:
Table of Contents

Advertisement

Menu
Feature
Item
17
Aux 2 Linking
18
Aux 2 Timed Output
19
Aux 3 Icon
20
Aux 3 Output Type
21
Aux 3 Linking
22
Aux 3 Timed Output
23
Aux 4 Icon
24
Aux 4 Output Type
25
Aux 4 Linking
26
Aux 4 Timed Output
27
Aux/Trunk Icon
28
Aux/Trunk Output Type
Remote keypad unlock-
29
ing
30
Transmitter Programming
OEM Alarm Disarm
31
With Unlock
Note: Features can only be programmed via the web tool. See "Connecting the module" on page 9 for more
information.
1
Ignition Controlled Locks
2
Door Lock Pulses
3
Door Lock Output Dura-
tion
4
2nd Unlock
5
Comfort Closure
6
Hood Trigger Type
7
Ignition Controlled
Domelight
8
OEM Alarm Disarm w/
Aux-Trunk
20
Opt. 1
Opt. 2
Refer to Aux 1 Linking.
Refer to Aux 1 Timed Output.
Refer to Aux 1 Icon.
Refer to Aux 1 Output Type.
Refer to Aux 1 Linking.
Refer to Aux 1 Timed Output.
Refer to Aux 1 Icon.
Refer to Aux 1 Output Type.
Refer to Aux 1 Linking.
Refer to Aux 1 Timed Output.
Refer to Aux 1 Icon description. The default value is Trunk.
Validity
Off
Off
On
Unlocked
Locked
Disable
Enable
Off: door lock/unlock outputs will NOT be activated when ignition is turned on/off.
1.
2.
Lock & Unlock: lock/unlock outputs will be activated when ignition is turned on/off.
3.
Lock Only: lock output will be activated when ignition is turned on.
4.
Unlock Only: unlock output will be activated when ignition is turned off.
Single: door lock/unlock outputs will pulse once.
1.
2.
Double Unlock Only: unlock output only will pulse twice.
3.
Double Lock Only: lock output only will pulse twice.
4.
Double Lock & Unlock: lock/unlock outputs will pulse twice.
1.
0.8sec.: door lock output pulses will be 800mS in duration.
2.
3.5sec.: lock pulses will be 3.5 seconds in duration.
3.
0.4 sec.: lock pulses will be 400mS in duration.
Off.
1.
2.
On w/delayed Ignition Control Output: for ignition controlled unlocking this output will pulse 0.8
seconds after the first unlock.
3.
On w/immediate Ignition Control Output: for ignition controlled unlocking this output will pulse at the
same time as first unlock.
No Comfort Closure: Comfort Closure is deactivated when arming.
1.
2.
Comfort Closure 1: door lock pulse (or 2nd pulse for double pulses) will remain on for 20 seconds.
3.
Comfort Closure 2: 800mS following the end of the door lock pulse (or 2nd pulse for double pulses);
the door lock output will turn on again for 20 seconds.
1.
Normally Open: vehicles with a hood switch that rests at ground when the hood is OPEN.
2.
Normally Closed: vehicles with a hood switch that rests at ground when the hood is CLOSED.
1.
Off: dome light output will NOT be activated when the ignition is turned off.
2.
On: dome light output will be activated when the ignition is turned off. It will be activated for 30
seconds, until the alarm is armed or until the ignition is turned on.
Off: OEM Alarm Disarm wire will NOT pulse when the Aux/Trunk output is activated.
1.
2.
On: OEM Alarm Disarm wire will pulse as programmed when the Aux/Trunk output is activated.
Opt. 3
Opt. 4
Opt. 5+
XpressStart ONE 4x10/5x10 Analog
© 2013 Directed. All rights reserved.

Advertisement

Table of Contents
loading

Table of Contents