Remote Pairing; Reset/Delete Remotes From Memory - Directed XPRESSSTART ONE Installation Manual

4x10/5x10
Hide thumbs Also See for XPRESSSTART ONE:
Table of Contents

Advertisement

Startup Diagnostics: If the vehicle fails to activate the remote start, the module will notify you via your remote con-
trol, and will flash the parking lights on the vehicle to notify you of what caused the no-start situation.
Parking Light
Definition
Flashes
5
Brake wire is active.
6
Hood pin wire is active.
7
Manual transmission mode is enabled and not initialized.
8
Neutral safety wire is not connected to ground or the neutral safety switch is off.

Remote pairing

For information on how to pair a specific remote, please refer to its corresponding owner documentation, which
can be found on www.directechs.com.

Reset/delete remotes from memory

If a feature/virtual tach needs to be reset or the remote controls need to be deleted, use the following procedure:
1. Open a door (in the case of a 5x10 system, Door Input must be detected).
2. Turn the ignition to the ON position.
3. Within 10 seconds, press and release the Control button: 2 times if you want to delete remotes, 3 times to
reset features or 4 times to reset virtual tach. These features are described next.
Delete remotes: This feature erases all remotes from the memory of the security system. This is useful in cases
when a customer's remote is lost or stolen.
Note: This does not reset the programmed features of the security system or reset the Virtual Tach setting.
Virtual Tach Reset: Deletes all previously learned values for Virtual Tach, and on the next remote start sequence
the unit begins virtual tach initialization.
4. Once you have selected the function step, press the Control button once more and hold it. The LED flashes and
the siren chirps to confirm the selected functional step. The Control button can be released.
5. In the case of a reset operation, press any button on the remote control. The unit chirps to confirm that the
feature has been successfully reset.
Once the feature is reset, turn the ignition off or close the door to exit the procedure.
Long-term event history
The system stores the last two full alarm triggers in memory. Each new trigger is added to the history while the oldest
are deleted. Trigger history is reported in order of newest to oldest. To access long term event history:
1. With the ignition Off, press and hold the Control button (on the Control Center).
2. Turn the ignition On.
3. Release the Control button.
4. Within 5 seconds, press and release the Control button. The status LED flashes in groups indicating the trig-
gered zones for 1 minute or until the ignition is turned off. Refer to table of zones.
Note: The Warn Away triggers are not stored to memory and is not reported.
24
XpressStart ONE 4x10/5x10 Analog
© 2013 Directed. All rights reserved.

Advertisement

Table of Contents
loading

Table of Contents