Connecting The Module; Important; Manual/Automatic Transmission Type; When Used In Conjunction With Smartstart - Directed XPRESSSTART ONE Installation Manual

4x10/5x10
Hide thumbs Also See for XPRESSSTART ONE:
Table of Contents

Advertisement

Connecting the module

Important!

Before connecting the 4x10/5x10 module, it is important to ensure that the proper feature and function program-
ming is selected using XpressVIP (version 4.5 or higher). Visit www.xpresskit.com to download the latest version of
the application.
To make this selection:
1. Disconnect the 4x10/5x10 module from any (+)12v power source, then connect it to your computer using
the XKLoader2.
2. Open an Internet browser and go to www.xpresskit.com; the programming window will be displayed auto-
matically.
3. Follow the instructions in the pop up window that will be displayed when the module is detected.
Note: If the latest firmware is already loaded, only the feature options will be flashed. Check the Yes box if
you wish to flash the firmware as well.
Once the module is programmed, you can proceed with the instructions below.

Manual/Automatic transmission type

Before
connecting the main power harness, the state of the yellow loop (cut/uncut) will set the modules transmission
type operation:
• Uncut: Manual transmission
• Cut: Automatic transmission
By default, all modules are shipped out with the yellow loop uncut (manual transmission). It is important to discon-
nect and reconnect the white12-pin main power harness on the module once the loop is cut, in order to complete
the transmission type switch.

When used in conjunction with SmartStart

The 4x10/5x10 module must be disconnected from any power source before SmartStart can be connected to it.
Failing to do so could damage the 4x10/5x10.
To ensure that the D2D communication between 4x10/5x10 and SmartStart works properly, one of the following
actions must be executed, depending on the hardware you are using:
• Rev A SmartStart – The brown or blue loop must be cut.
• Rev B SmartStart – The gray wire must be connected to a ground source.
Do NOT connect the 2-pin harness (on SmartStart). Power and ground will be provided by the 4x10/5x10 D2D
connector.
9
XpressStart ONE 4x10/5x10 Analog
© 2013 Directed. All rights reserved.

Advertisement

Table of Contents
loading

Table of Contents