Chapter 20 — Meridian Mail Compact Option installation and maintenance
Table 32 DSP parameters
DSP parameter name
DSP encoding type
Disable silence compression
Transmit level
Receive level
DTR reject level
*DTR Max accept level
Disable AGC
*AGC center
Hook flash pulse
Telescan debounce
Telescan ring time
Option 11C Compact
Step
4
At the prompt "Select operation:"
IF you select
Done
Change or Reset
Default value
Mulaw
No
0
0
-57
1
No
-20
320
128
1024
Note: DSP parameters marked with an "*" cannot be modified. They are
reserved for future use.
Action
Range
Mulaw, Alaw
No, Yes
-10 to +10 dBm
-10 to +10 dBm
-60 to - 30 dB (increments of 3 dB)
-11, -8, -5, -2, 1, or 4 dBm
No, Yes
-20 to -10 dBm
304, 320, 336, . . . 1024 (increments of 16)
96, 112, 128, . . . 512 (increments of 16)
224 to 1024 (increments of 16)
Planning, Installation, Fault Clearing and CCBR Guide
Page 237 of 536
THEN go to
next procedure.
step
3.