Page 510 of 536
Possible cause
Defective NTMW01 SSC
card
Excessive traffic in the
system
Clearing attendant console faults
Attendant console faults
553-3121-210
Standard 3.0
Chapter 25 — Fault locating and clearing
Action
Use the attendant console Barge-in to seize trunks and audibly
test for dial tone and outpulsing, or use a maintenance telephone
and enter
LD 36
TRK c u
("c u" represents card and unit numbers)
Note: See the Option 11C Compact software guide for information
on using this test.
If you do not hear outpulsing or tone replace the NTMW01 SSC
card.
Additional trunk circuit cards may be required to handle the traffic
in the system.
Components that can cause an attendant console fault are:
•
the console itself or add-on units
•
the console power supply
•
the building wiring
•
the cross-connect from the console to the line circuit
•
the unit on the peripheral line circuit card
•
the peripheral line circuit card
•
the ringing generator
•
the cabinet power supply
If more than one attendant console is affected, look for connections such as:
•
they are on the same line circuit card
•
there is a problem with ringing or tones
January 1999