Connecting an attendant console

553-3121-210
Standard 3.0
Chapter 17 – Connecting the telephones and attendant console
4
Cross-connect the J1 cable to the Tip and Ring connections
coming from the line card.
Refer to
Tables 20
5
Cross-connect the J2 cable to the off-premise telephone.
6
Install the regulatory label provided with the Off-Premise
protection module on the inside right-hand wall of the cabinet
near the velcro wriststrap fastener.
7
Install the line card in its assigned position.
The telephone can now be activated as described in
telephones" on page
—————————— End of Procedure ——————————
Procedure 23 describes how to connect an attendant console to an NTMW05
line card.
Procedure 23
Connecting attendant console
1
Locate the attendant console terminations at the cross-connect
terminal.
2
Locate the line card terminations at the cross-connect terminal.
3
With cross-connect wire, connect the line card and other
connections to the console as shown in
—————————— End of Procedure ——————————