PGR-YMCK
Setting value of transfer bias between sheets (Y, M, C, Bk)
[When used]
The density of the entire area of 70 to 80mm from the leading edge of the sheet is low/high, or there are an infinite number of white or black spots in
an image when the entire print is halftone, etc.
[Adjustment method]
- The problem may be eliminated by changing the setting value.
- Increase the setting value. (Effective for thin density in the area 70 to 80mm from the leading edge)
- Decrease the setting value. (Effective for high density in the area 70 to 80mm from the leading edge)
Setting range: -20 to 50 (Unit: 50V)
[Factory setting value/Value after RAM clearing: 0]
FRT-ATH
Attraction bias front side setting value
[When used]
An image failure occurs depending on the type or condition of the paper AND the problem cannot be eliminated by performing special printing
process.
[Adjustment method]
- The problem may be eliminated by changing the setting value.
Setting range: -20 to 20 (Unit: 100V)
[Factory setting value/Value after RAM clearing: 0]
BCK-ATH
Attraction bias backside setting value
[When used]
An image failure occurs depending on the type or condition of the paper AND the problem cannot be eliminated by performing special printing
process.
[Adjustment method]
- The problem may be eliminated by changing the setting value.
Setting range: -20 to 20 (Unit: 100V)
[Factory setting value/Value after RAM clearing: 0]
FRFS-TMP
Fixing temperature front side setting value
[When used]
The problem cannot be eliminated by performing special printing process and the image is not firmly fixed to the sheet, or a residual image remains
in the image.
[Caution] The fixing heater temperature is changed via this mode, and therefore, attentions should be paid when using this mode.
[Adjustment method]
- When an image is not firmly fixed to the sheet, the problem may be eliminated by increasing the setting value.
- When a residual image remains in an image, the problem may be eliminated by decreasing the setting value.
Setting range: -4 to 4 (Unit: Approx. 5 degree C)
[Factory setting value/Value after RAM clearing: 0]
BKFS-TMP
Fixing temperature backside setting value
[When used]
The problem cannot be eliminated by performing special printing process and the image is not firmly fixed to the sheet, or a residual image remains
in the image.
[Caution] The fixing heater temperature is changed via this mode, and therefore, attentions should be paid when using this mode.
[Adjustment method]
- When an image is not firmly fixed to the sheet, the problem may be eliminated by increasing the setting value.
- When a residual image remains in an image, the problem may be eliminated by decreasing the setting value.
Setting range: -4 to 4 (Unit: Approx. 5 degree C)
[Factory setting value/Value after RAM clearing: 0]

16.2.4 FUNCTION

16.2.4.1 FUNCTION List

imageCLASS MF9170c / imageCLASS MF9150c / imageCLASS MF8450c
<INSTALL>
Sub item
CARD
Not used
E-RDS
Enabling/disabling of the e-RDS function
Setting value: 0: Disabled, 1: Enabled
[Factory setting value/Value after RAM clearing: 0]
RGW-PORT
Setting of the port number of the sales company's server used for E-RDS
Refer to the port number in the user mode.
Setting range: 1 to 65535
[Factory setting value/Value after RAM clearing: 443]
COM-TEST
Confirmation of the connection with the sales company's server used for E-RDS
Try to connect the sales company's server. Make a judgment of whether connection has been made or not, and display the result by OK or NG.
COM-LOG
Display of a communication error log
Display the detailed result of communication test with the sales company's server used for E-RDS.
When an error occurs in communication with the sales company's server, error information is displayed.
<Log contents>
Number: No. 1 is assigned to the latest one.
Error code: 8-digit hexadecimal number
Date: Date when the error occurred
Time: Time when the error occurred
Detailed error information: 128 characters maximum
5 logs maximum
RGW-ADR
Setting of the URL of the sales company's server used for E-RDS
Set the URL of the sales company's server.
Setting value: URL (incl. NULL, SJIS is not supported) (128 characters maximum)
COPIER > ADJUST > VIFADJ
Description
T-16-9
COPIER > FUNCTION > INSTALL
Description
Chapter 16
0020-2015
16-11