Chapter 16
Numb
er
17
Upper limit for F/T calling time
19
Number of trail edge margin (lines) at image's trail edge
20
Time to capture F/T line
24
Delivery time for V34 control cannel flag
25
Delivery time for V34 primary channel flag
26
V34 fallback speed
27
Number of PPR to start V34 fallback
30
T2 timer
40
Setting T2 timer value for V34 communication
41
Synchronization interval for RETRY to use for synchronization of V8 procedure signal 'PC -> CC' at
the time of receiving FAX
44
Number of times of RETRY to use for synchronization of V8 procedure signal 'PC -> CC' at the time
of receiving FAX
45
Wait time when the DT detection function that is executed before calling is disabled
46
Time to identify DialTone signal
47
Time of not being disconnected in the case that DialTone signal is disconnected
65
Number of maximum lines of A4 paper at the time of sending cut paper
66
Number of maximum lines of B4 paper at the time of sending cut paper
<RKEY>
(1) Numeric parameter
Parameter No.
01
02
<PBX DIAL TONE>
(1) Bit switch
Bit No.
0
1
2
3
4
5
6
7
(2) Numeric parameter
Parameter No.
01
02
03
04
05
06
07
08
<PBX BUSY TONE>
(1) Bit switch
Bit No.
0
1
2
3
4
5
6
7
16-34
Setting Description
T-16-54
Function
Flash connection time
Grounding time
T-16-55
Function
Frequency sensing method
Signal frequency
Screening intermittent signal
Signal format
Signal sensing
T-16-56
Function
T0 timer
T1 timer
T2 timer
T3 timer
T4 timer
Signal sensing table
Signal sensing level
Number of signal frequencies
T-16-57
Function
Signal frequency
Screening intermittent signal
Signal format
Signal sensing
0 to 9999 (sec)
0 to 9999 (lines)
0 to 9999 (sec) Special SW17 bit 4
0 to 100 (x 10 ms)
20 to 500 (x 10 ms)
1 to 4 (x 2.4 kbps)
1 to 9 (times)
6 to 30 (sec)
0 to 9999 (x 10 ms)
0 to 9999 (x 10 ms)
1
Modem
Changes
From ON
Continuous
Yes
0 to 9999 (x 10 ms)
0 to 9999 (x 10 ms)
0 to 9999 (x 10 ms)
0 to 9999 (x 10 ms)
0 to 9999 (x 10 ms)
0 to 16
0 to 9
0 to 9999 (pce)
1
Changes
From ON
Continuous
Yes
Setting Range
Setting Range
0
Tonal counter
No change
From both
Intermittent
No
Setting Range
0
No change
From both
Intermittent
No