Chapter 14
No.
Tx/Rx
##0237
[Rx]
##0261
[Tx]
##0282
[Tx]
##0283
[Tx]
##0288
[Tx]
##0289
[Tx]
##0290
[Tx]
##0670
[Tx]
##0671
[Rx]
##0672
[Tx]
##0673
[Rx]
##0674
[Tx]
##0675
[Rx]
##0752
[Tx]
##0753
[Tx]
##0754
[Tx]
##0757
[Tx]
##0758
[Tx]
##0759
[Tx]
##0762
[Tx]
##0763
[Tx]
##0764
[Tx]
##0767
[Tx]
##0768
[Tx]
##0769
[Tx]
##0772
[Tx]
##0773
[Tx]
##0774
[Tx]
##0778
[Tx]
##0779
[Tx]
##0782
[Tx]
##0783
[Tx]
##0784
[Tx]
##0787
[Tx]
##0788
[Tx]
##0789
[Tx]
##0790
[Rx]
##0791
[Tx]
##0792
[Rx]
##0793
[Rx]
##0794
[Tx]
##0795
[Tx]
14-10
Description
decoding error has occurred.
system error has occurred.
at time of transmission, the procedural signal has been transmitted more than specified.
at time of transmission, the procedural signal has been transmitted more than specified.
after transmission of EOP, a signal other than PIN, PIP, MCF, RTP, or RTN has been received.
after transmission of EOM, a signal other than PIN, PIP, MCF, RTP, or RTN has been received.
after transmission of MPS, a signal other than PIN, PIP, MCF, RTP, or RTN has been received.
at time of V.8 late start, the V.8 ability of DIS front the receiving party is expected to be detected, and the CI signal is expected
to be transmitted in response; however, the procedure fails to advance, and the line is released because of T1 time-out.
at time of V.8 arrival, procedure fails to move to phase 2 after detection
releasing line
at time of V.34 transmission, a shift in procedure from phase 2 to phase 3 and thereafter stops, causing the machine to release
the line and suffer T1 timeout.
at time of V.34 reception, a shift in procedure from phase 2 to phase 3 and thereafter stops, causing the machine to release the
line and suffer T1 timeout.
at time of V.34 transmission, a shift in procedure from phase 3 and phase 4 to the control channel and thereafter stops, causing
the machine to release the line and suffer T1 timeout.
at time of V.34 reception, a shift in procedure from phase 3 and phase 4 to the control channel and thereafter stops, causing the
machine to release the line and suffer T1 timeout.
at time of ECM transmission, DCN is received after transmission of PPS-NULL.
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-NULL,
or T5 time-out (60 sec) has occurred.
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-NULL.
at time of ECM transmission, DCN is received after retransmission of PPS-MPS.
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-MPS, or
T5 time-out (60 sec) has occurred.
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-MPS.
at time of ECM transmission, DCN is received after transmission of PPS-EOM.
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-MPS, or
T5 time-out (60 sec) has occurred.
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-EOM.
at time of ECM transmission, DCN is received after transmission of PPS-EOP.
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-EOP, or
T5 time-out (60 sec) has occurred.
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-EOP.
at time of ECM transmission, DCN is received after transmission of EOR-NULL.
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of EOR-NULL,
or T5 time-out (60 sec) has occurred.
at time of ECM transmission, ERR is received after transmission of EOR-NULL.
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission EOR-MPS, or
T5 time-out (60 sec) has occurred.
at time of ECM transmission, ERR is received after transmission of EOR-MPS.
at time of ECM transmission, DCN is received after transmission of EOR-EOM.
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of EOR-EOM,
or T5 time-out (60 sec) has occurred.
at time of ECM transmission, ERR is received after transmission of EOR-EOM.
at time of ECM transmission, DCN is received after transmission of EOR-EOP.
at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of EOR-EOP, or
T5 time-out (60 sec) has occurred.
at time of ECM transmission, ERR is received after transmission of EOR-EOP.
at time of ECM reception, ERR is transmitted after transmission of EOR-Q.
while ECM mode procedure is under way, a signal other than a meaningful signal is received.
at time of ECM reception, PPS-NULL cannot be detected over partial page processing.
at time of ECM reception, no effective frame is received while high-speed signal reception is under way, thus causing time-out.
at time of ECM reception, PPR with all 0s is received.
a fault has occurred in code processing for communication.
of CM signal from caller, causing T1 time-out and

Advertisement