5 Configuring Communication Connections
5.7.2

Specifying UDP Addresses

Address Parameters and Connection Types
With UDP, the communication partners are addressed using the local and remote
endpoint, as follows.
S Local addresses:
Local IP address and local port
S Remote addresses:
Remote IP address and remote port
Note
The term "connection" is also used here for UDP. Reason:
During configuration (just as in TCP) the communication partners are assigned to
each other and therefore logically "connected". In actual fact, with UDP there is no
explicit connection establishment between communication partners.
Ethernet station A
Figure 5-19
Sending and Receiving on One UDP Connection
Depending on the required connection type, the remote address parameters are
either specified or left open during configuration.
S Specified UDP connection
You specified a destination station when you created the connection.
Configuring broadcast or multicast provides you with a further option (see
Section 5.7.3 below).
S Unspecified UDP connection
You entered "unspecified" for the connection partner when you created the
connection.
A -142
remote
port
UDP
connection
local
port
MAC
address A
S7-CPs for Industrial Ethernet Configuring and Commissioning
Ethernet station B
local
port
remote
port
IP
address B
C79000-G8976-C182-07