Siemens SIMATIC NET S7-300 Manual page 168

Cps for industrial ethernet
Hide thumbs Also See for SIMATIC NET S7-300:
Table of Contents

Advertisement

6 Programmed Communication Connections
6.4
Parameter Field for System Data
(CP Networking)
Meaning
Below, you can see the subfields that are relevant for networking the CP. These
must be specified in the parameter field for system data.
Some applications do not require all the subfield types - refer to the table for
details.
Structure
Usable Subfields
Table 6-4
Subfield
ID
1
SUB_IP_V4
2
SUB_NETMASK
8
SUB_DEF_ROUTER
4
SUB_DNS_SERV_ADDR
14
SUB_DHCP_ENABLE
15
SUB_CLIENT_ID
*) The general properties of the subfield types are described below in Section 6.6.
A -168
Type = 0
ID = 0
Number of subfields = n
Subfield 1
Subfield 2
Subfield n
*)
Type
(Please refer also to the general
description in Table 6-10 Page A -177)
Local IP address
-
-
This subfield can occur from 0 to 4 times.
The first entry is the primary DNS server.
0: No DHCP
1: DHCP
-