GE PanaFlow HT User Manual page 132

Ultrasonic liquid flowmeter
Hide thumbs Also See for PanaFlow HT:
Table of Contents

Advertisement

Register
Register (in
(in Hex)
Decimal)
AE18
44568
AE1A
44570
AE1C
44572
CH Integer Min
AF00
44800
AF02
44802
AF04
44804
AF06
44806
AF08
44808
AF0A
44810
AF0C
44812
Ultrasonic Files
A000
40960
A001
40961
A002
40962
A003
40963
A004
40964
A010
40976
A011
40977
A012
40978
A013
40979
A014
40980
PanaFlow HT User's Manual
Table 10: XMIT Modbus Map (cont.)
Access
Level
VIEWER
Minimum Channel_SNR on UP channel 18
VIEWER
Minimum Channel_SNR on DOWN
channel
VIEWER
Minimum Channel Time in buffer on UP
channel
VIEWER
Minimum Channel status bit map
VIEWER
Minimum Channel Up +- Peak
VIEWER
Minimum Channel Dn +- Peak
VIEWER
Minimum Channel most significant
error
VIEWER
Minimum Channel dynamic threshold
on UP channel
VIEWER
Minimum Channel dynamic threshold
on DOWN channel
VIEWER
Minimum Channel #Errors of Last 16
VIEWER
Channel 1 Raw Up
VIEWER
Channel 1 Raw Down
VIEWER
Channel 1 Correlate Up
VIEWER
Channel 1 Correlate Down
VIEWER
Channel 1 CrossCorrelation
VIEWER
Channel 2 Raw Up
VIEWER
Channel 2 Raw Down
VIEWER
Channel 2 Correlate Up
VIEWER
Channel 2 Correlate Down
VIEWER
Channel 2 CrossCorrelation
Variable
Unit Group
18
19
18
18
18
18
12
12
18
18
18
18
18
18
18
18
18
18
18
Appendix C. Modbus Map
Read Only/
Read Write
Format
RO
(IEEE 32 bit)
RO
(IEEE 32 bit)
RO
(IEEE 32 bit)
RO
INT32
RO
INT32
RO
INT32
RO
INT32
RO
INT32
RO
INT32
RO
INT32
RO
signed short
RO
signed short
RO
signed short
RO
signed short
RO
signed short
RO
signed short
RO
signed short
RO
signed short
RO
signed short
RO
signed short
123

Hide quick links: