Cooling Fans; Removing A Cooling Fan - Dell PowerEdge XR12 Installation And Service Manual

Table of Contents

Advertisement

Figure 82. Installing the drive cage
Next steps
1.
Install the
backplane.
2.
Install the
drives.
3. Follow the procedure listed in

Cooling fans

Removing a cooling fan

Prerequisites
1. Follow the safety guidelines listed in the
2. Follow the procedure listed in the
3.
Remove the expansion card riser
4.
Remove the air
shroud.
5. Move the cables out of way to access the fan cable connector on the system board or the PIB.
NOTE:
Observe the fan cable routing or make a note on the fan cable routing.
NOTE:
The procedure to remove the cooling fan is the same for Rear Accessed and Front Accessed configurations.
Steps
1. Disconnect the cooling fan cable that is connected on the system board connector or the power interposer board (PIB).
NOTE:
Fans 1, 2, and 3 are connected on the PIB and fans 4, 5, and 6 are connected on the system board.
2. Holding the blue touch point, lift the cooling fan out of the fan cage.
74