Figure 84. Installing a cooling fan
Next steps
1.
Install the air
shroud.
2.
Install the expansion card riser
3. Follow the procedure listed in

Intrusion switch module

This is a service technician replaceable part only.

Removing the intrusion switch module

Prerequisites
1. Follow the safety guidelines listed in the
2. Follow the procedure listed in the
NOTE:
The procedure to remove the intrusion switch module is the same for Rear Accessed and Front Accessed
configurations.
Steps
1. Disconnect and remove the intrusion switch cable from the connector on the power interposer board (PIB).
NOTE:
Observe the routing of the cable as you remove them from the system.
2. Using the Phillips #1 screwdriver, remove the screw securing the intrusion switch module.
3. Lift the intrusion switch module out of the system.