System diagnostics and indicator codes
This section describes the diagnostic indicators on the system front panel that displays the system status during system startup.
Topics:

Status LED indicators

System health and system ID indicator codes
iDRAC Direct LED indicator codes
NIC indicator codes
Power supply unit indicator codes
Drive indicator codes
Using system diagnostics
Status LED indicators
NOTE:
The indicators display solid amber if any error occurs.
Figure 139. Status LED indicators
Table 34. Status LED indicators and descriptions
Icon
Description
Drive indicator
Temperature
indicator
Electrical
indicator
Condition
The indicator turns solid amber if
there is a drive error.
The indicator turns solid amber if
the system experiences a thermal
error (for example, the ambient
temperature is out of range or
there is a fan failure).
The indicator turns solid amber
if the system experiences an
electrical error (for example,
Corrective action
● Check the System Event Log to determine if the
drive has an error.
● Run the appropriate Online Diagnostics test.
Restart the system and run embedded
diagnostics (ePSA).
● If the drives are configured in a RAID array,
restart the system, and enter the host adapter
configuration utility program.
Ensure that none of the following conditions exist:
● A cooling fan has been removed or has failed.
● System cover, air shrouds, or back filler bracket
has been removed.
● Ambient temperature is too high.
● External airflow is obstructed.
If the problem persists, see the
Check the System Event Log or system messages
for the specific issue. If it is due to a problem with
System diagnostics and indicator codes
9
Getting help
section.