4.4. IMPORT / EXPORT OF WELDING PROGRAMS

The export of welding programs can be useful to import those programs on another welding post, or to conserve a back up of those programs on an
external storage medium.
An exported program is associated to its number among the 100 available numbers. If a program is linked to a user synergy, this synergy will be
automatically exported and imported with this program.
An imported program on a power source is sent to its original number and erases, if, the initial program associated to the same number.
Let's take the example of the import of programs 1 and 2 among the 100 programs of a power source A to another power source B:
The program 1
is imported and keep this number.
A
The program 2
has erased the program 2
A
The program 42
est conservé car aucun programme 42 n'est présent dans A..
B
In this example, the programs of the power source B are not identical with the ones of the power source A because the program 42 has been kept. To
obtain identical programs between A and B, suppress all the programs of the power source B before making the import.
FREE mode
The DIGIWAVE II has a free mode in which the operator can access additional welding parameter settings. This allows you to adjust the generator for
particular applications.
Additional settings smooth running:
• Arc Voltage / Tension crête
• Dynamism
Additional settings pulsed current:
By placing the cursor on SPEED WIRELESS, pressing OK shows the parameters together to facilitate the adjustment of parameters
• Frequency
• Time pulse
• Basic current
In free mode the generator is no longer a synergistic fashion. Thereby welding behavior is directly related to values
set by the operator. This mode should only be used by qualified technicians
4.5. USERS MANAGEMENT & TRACEABILY
USERS PROFILES PRESENTATION
By default, on the first start up of the power source, the list of users is empty. In this case, every user can use the power source and access freely every
function and the generated trace files are anonymous.
When it is necessary to identify the generated trace files, to grant use limitations to certain users, or to avoid the use of the power source to a non
identified user, you can create users with adapted levels of rights. It is possible to come back to an empty list in: Maintenance > Factory Reset > User
database
26
A
1
Program 1
A
2
Program 2
A
.
.
.
42
.
.
.
100
. Le programme 2
est perdu
B
B
B
1
2
Program 2
B
.
.
.
42 Program 42
B
.
.
.
100
WARNING
B
1
Program 1
A
2
Program 2
A
.
.
.
42 Program 42
B
.
.
.
100
DIGIWAVE II

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents