4.7. CONTROL PROCESS

The Control Process allows improving the control of the welding variables. Indeed, the DigiWave II is able to alert the user that the value of one of the
following variables is out of a control corridor:
-
Current welding
-
Current of the wirefeeder motor (gives an idea of the wire speed)
-
Arc tension
The control corridor is defined by an upper threshold and a lower threshold that the user can tune for each variable. To tune them, the user can refer to the
minimum and maximum values measured during the previous weld. Those values are accessible in the menu: "Tuning Help".
A fault message is triggered if the time of the outputs on the same upper limit to a control inhibition time T (s)
In the example below, the upper limit is exceeded two times t1 <T and t2> T.
Only t2 exceeded triggers the default
The Control Process page is accessible in the SETUP of the MIG menu. You can choose to activate the control only on certain variables.
To set the threshold values, you can refer to the minimum and maximum values measured during the previous weld. Those values are accessible in the
menu: "Tuning Help".
The control process parameters are associated to one welding program. Those parameters can be different from one program to another.
There are three types of fault detection defined in the menu Configuration > Installation > Fault
Type
Blocking
Immediate blocking as soon as a fault is detected
Fault display at the end of the weld that disappears with
Indicative
acquittal or when a new cycle starts.
No-Blocking
No visible effect, only searchable in fault history
All faults are stored in the history. The following data is available:
-
Failure
-
Fault number
-
Controlled variable
-
Program number
-
Date / Time
-
User identified
-
Maximum value reached
-
Total length of the fault
-
Total length cumulative defects on the variable
When the process control is activated, a colored dot appears next to the controlled variable on the page in MIG welding. If the dot remains green during
welding, no defects were found, otherwise it becomes red.
DIGIWAVE II
Effect
E = Déclenchement de défaut
Content of the displayed window
-
Extreme value reached by the variable
-
Fault duration = Inhibition time
For each variable and each detected fault:
-
Extreme value reached
-
Total duration
Last line: cumulative faults duration.