Harnesses - Air Liquide SAF-FRO DIGIWAVE II Instruction For Operation And Maintenance

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

8.15. HARNESSES

AIR harness 2 M – 70 MM
AIR harness 5 M – 70 MM
AIR harness 10 M – 70 MM
AIR harness 15 M – 70 MM
AIR harness 25 M – 70 MM
AIR harness 30 M – 70 MM
AIR harness 40 M – 70 MM
AIR harness 50 M – 70 MM
WATER harness 2 M – 95 MM
WATER harness 5 M – 95 MM
WATER harness 10 M – 95 MM
WATER harness 15 M – 95 MM
WATER harness 25 M – 95 MM
WATER harness 50 M – 95 MM
WATER ALU harness 2 M – 95 MM
WATER ALU harness 5 M – 95 MM
WATER ALU harness 10 M – 95 MM
WATER ALU harness 15 M – 95 MM
WATER ALU harness 25 M – 95 MM
For all harness : during welding
2
For harness 70 MM
, I MAX =
For harness 95 MM
2
, I MAX =
DIGIWAVE II
2
2
2
2
2 (in order)
2 (in order)
2 (in order)
2 (in order)
2
2
2
2
2 (in order)
2
2
2
2
2
2
OK
100% 60%
310A 350A
355A 400A
100% 60%
370A 430A
430A 500A
ref. W000275894
ref. W000275895
ref. W000275896
ref. W000275897
ref. W000276901
ref. W000371246
ref. W000371245
ref. W000371244
ref. W000275898
ref. W000275899
ref. W000275900
ref. W000275901
ref. W000276902
Consult us
ref. W000371044
ref. W000371045
ref. W000371175
ref. W000371174
ref. W000371239
WARNING
35%
T° Amb.
420A
40°C
480A
25°C
35%
T° Amb.
520A
40°C
600A
25°C
40

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents