Dometic OPTIMUS 360 Installation Manual page 69

Joystick control system for engines with integrated electronic shift and throttle
Hide thumbs Also See for OPTIMUS 360:
Table of Contents

Advertisement

EN
3. Select Calibrate Main EST Gateway and press >. This will put the
main station gateway into calibration mode.
Figure 9-7.
a. Forward WOT – move the levers to the forward throttle stops
b. Forward detent – engage forward gear with levers in idle position
c. Neutral – put both levers in neutral
d. Reverse detent – engage reverse gear with levers in idle position
e Reverse WOT – move levers to the reverse throttle stops
5. After the final calibration step the wizard will exit automatically.
6. Repeat the calibration wizard from the second station, if applicable.
9-7