8-6
2. At the main station CANtrak, navigate to Dealer Menu > Initial Setup
> EST Gateway to bring up the EST Gateway Setup screen. If you
have two gateways, and have correctly set the number of gateways in
section 4, then you will also see a 2nd station gateway on your screen.
Figure 8-7.
3. Select Calibrate Main EST Gateway and press >. This will put the
main station gateway into calibration mode.
Figure 8-8.
4. The status indication will guide you through the calibration steps.
Move both control levers to the position indicated in the status field.
You will be directed in turn through the following:
a. Forward WOT – move the levers to the forward throttle stops
b. Forward detent – engage forward gear with levers in idle position
c. Neutral – put both levers in neutral
d. Reverse detent – engage reverse gear with levers in idle position
e. Reverse WOT – move levers to the reverse throttle stops
5. After the final calibration step the wizard will exit automatically.
6. Repeat the calibration wizard from the second station, if applicable.
EN