IF NO CANtrak 2
TO MAIN STATION
TO GATEWAY
MASTER SUB
DBW
Figure 6-5. Suzuki EST 2nd station, quad engines.
EN
2nd STATION
BUZZER
HELM
REQUIRED
2
SUB PORT
BCM
CONTROL
HEAD 2
SUB STBD
BCM
TO GATEWAY
SLAVE SUB
DBW
6.2.1

Suzuki BCM CAN network connection

Locate the Suzuki CAN connection point on the Suzuki Main BCM harness
behind the main station dash. Look for a twisted pair of wires (white and
black) with a two-pin connector.
Single station boats – the connector will have a male network terminator
plug installed in it. Remove the terminator plug and insert the CM20018
harness plug labeled '1st Station'. Install the terminator plug in the
CM20018 harness receptacle labeled '2nd Station'. See figure 6-6.
Dual station boats – The connector will be connected to the Suzuki Sub
BCM harness. Break the connection and connect the two halves to the
CM20018 harness plugs. The Sub BCM harness will connect to the plug
labeled '2nd Station' and the Main BCM harness to the plug labeled '1st
Station.' See figure 6-6.
SUB PORT
KEYPAD
SUB STBD
KEYPAD
OPTIONAL 2nd STATION
COMPONENTS
COLOR
JOYSTICK
CANtrak 2
2
BUZZER
OPTIMUS CAN1
OPTIMUS CAN2
EST GATEWAY MASTER
EST GATEWAY SLAVE
6-5