Figure B-21. Start LPS calibration.
B-22
2. The LPS Calibration Status
field will change to read
'Cal in Progress,' and the
Calibration Step field will
read 'Forward WOT' as
shown in figure B-22.
3. Move both control levers
to the forward WOT
position. The Calibration
Step Status will change
from 'Not Ready' to
'Ready.' (See figure B-23.)
Click Save Calibration
Point.
Figure B-22. LPS calibration forward WOT.
Figure B-23. Forward WOT Ready lever in position.