System Time-Outs - Graco Horizon Fluid Management Systems Instructions Manual

Table of Contents

Advertisement

System Setup - - System Time-outs
Instructions
Set System Time-outs
Unused Keypad Time-out
If enabled, the keypad time-out helps avoid having an
unauthorized person use an unattended keypad. An
unused keypad will automatically return to the HOME
screen after the set time elapses when it is in the run
or inventory modes, requiring that a valid password be
entered before re-accessing the run or inventory
screens.
The time-out set for the keypad applies to all keypads
connected to the system. If the time is left at 00, the
keypad time-out feature is disabled.
1. Cursor is in MINUTES field.
Dispense Time-out
NOTE: Dispense time-out cannot be set to zero; it is
always enabled. The time-out that is set will apply to
the entire system.
Dispense time-out provides a way to close a job once it
becomes active or waiting
The time set for dispense time-out represents the
amount of time the operator has to start dispensing the
job after it has been entered into the system. If there
are no meter pulses within the set amount of time, the
system will close the job.
The set time represents the amount of time the opera-
tor has to start dispensing the job after it has been
entered into the system. If there are no meter pulses
within the set amount of time, the system will close the
job.
1. Cursor is in MINUTES field.
Save the Setup
Follow the Save Setup procedure on page 30.
2. Type the number of minutes you want to elapse
before the time-out will occur.
3. Press ENTER to confirm the setting and go to the
Dispense Time-out screen.
Screens
UNUSED KEYPAD WILL
RETURN TO HOME
AFTER 00 MINUTES.
USE ENTER TO CONT.
2. Type the number of minutes you want to elapse
before the time-out will occur.
3. Press ENTER to confirm the setting and go to the
SAVE SETUP screen.
01 MINUTES TO START
DISPENSE AFTER ENTRY
OR CLOSE JOB AFTER
LAST METER PULSE
308607
39

Advertisement

Table of Contents
loading