System Setup - - Meter Calibration
Instructions
Set Meter Calibration
1. Cursor is in the METER NUMBER field.
2. The meter number will display according to the
order they were entered while assigning connec-
tions (page 34).
3. Press ENTER on the keypad.
4. Cursor moves to the CM# field.
5. Type the number of the control module that con-
trols the meter for this dispense point.
6. Press ENTER on the keypad.
7. Cursor moves to the PORT# field.
8. Type the number of the port the meter is con-
nected to (7--12).
9. Press ENTER on the keypad.
10. Cursor moves to the PULSES PER XX field.
11. Type the number of pulses (per unit of measure).
Only integers between 1 and 9999 will be
D
accepted for the calibration factor.
P/N 238618 Oil Meter has a nominal calibra-
D
tion factor of 200 pulses per quart (211 pulses
per liter).
P/N 215474 Meter (for antifreeze and washer
D
fluid) has a nominal factor of 10 pulses per
quart (11 pulses per liter).
Start with the nominal value and adjust the
D
value as needed to increase accuracy.
12. Press ENTER on the keypad.
13. When the cursor is at MORE, press ENTER to
repeat the screen for each meter.
-- Or move the cursor to EXIT to exit the connec-
tion assignment setup.
Save the Setup
Follow the Save Setup procedure on page 30.
Screens
METER NUMBER: 001
CM# 01
PORT# 07
0001
PULSES PER QT
MORE
EXIT
METER NUMBER: 001
CM# 01
PORT# 07
0001
PULSES PER QT
MORE
EXIT
METER NUMBER: 001
CM# 01
PORT# 07
0001
PULSES PER QT
MORE
EXIT
METER NUMBER: 001
CM# 01
PORT# 07
0001
PULSES PER QT
MORE
EXIT
METER NUMBER: 001
CM# 01
PORT# 6
0200
PULSES PER QT
MORE
EXIT
308607
35

Advertisement

Table of Contents
loading

Table of Contents