10

Pre-installation

10.1

Types of installation

Surface Installation

Surface Applied means that the operator and header are mounted on the surface of the wall, and
an external arm system is used to operate the door.
A surface applied header is typically 3" longer than the concealed in order to attach easily to
the jambs.
Standard installation is made with the distance 3 3/4" (95 mm) from hinge
High performance installation, used in windy conditions and heavy doors is made with the dis-
tance 8 1/4" (210 mm) from hinge
Retrofit installations may be done even with the distance of 2 3/4" (70 mm) from hinge
outgoing shaft.
10.2

General tips/Safety concerns

For enhanced security and vandalism protection, always mount the operator access in the
interior of a building whenever possible.
Make sure that the power is off before installing.
Make sure that the door leaf and the wall are properly reinforced at the installation points.
Inspect the door hinges before installation to ensure that they are in good repair.
Unpack the operator and make sure that all parts are delivered in accordance with the packing
note.
1007718-US-3.0
C L
to outgoing shaft.
Issue 2012-06-27
10 Pre-installation
C L
to outgoing shaft.
C L
to