Func-
Func-
Name
Name
code
code

Second Acceleration and Deceleration Functions

Second accelera-
A54
tion time setting
Second decelera-
A55
tion time setting
Two stage
acce1/dece1
A56
switching
method
selection
Acc1 to Acc2
frequency
A57
transition point
Decl to Dec2
frequency
A58
transition point
Acceleration
A59
curve selection
Deceleration
A60
curve setting
Description
Description
Duration of 2nd segment of acceleration,
range is 0.1 to 3000 sec.
Second acceleration can be set by the
[2CH] terminal input or frequeny
transition setting
Duration of 2nd segment of deceleration,
motor, range is 0.1 to 3000 sec.
Second acceleration can be set by the
[2CH] terminal input or frequeny
transition setting
Two options for switching from 1st to 2nd
accel/decel:
0.... 2CH input from terminal
1.... transition frequency
frequency acc1 acc2
2CH
Output frequency at which Accel 1
switches to Acce1 2, range is 0.00 to
400.0Hz in units of 0.01Hz.
Output frequency at which Decel 1
switches to Dece1 2, range is 0.00 to
400.0Hz in units of 0.01Hz.
Set the characteristic curve of Acc1 and
Acc2, two options:
0... linear, 1... S-curve, 2... U-curve
Target freq.
Linear
Set the characteristic curve of dec1
and dec2, two options:
0... linear, 1... S-curve, 2... U-curve
time
U-curve
S-curve
Run-
Run-
time
time
Defaults
Defaults
Edit
Edit
10.0sec
10.0sec
0