Terminal
Option
Symbol
Code
1
FA1
2
FA2
Valid for inputs:
Required setting
Notes:
At the time of acceleration, an arrival signal at
a frequency between the set frequency -0.5Hz
to +1.5Hz is turned on.
At the time of deceleration, an arrival signal at
a frequency between the set frequency +0.5Hz
to -1.5Hz is turned on.
The delay time of the output signal is 60ms
(nominal).
Function Name
Frequency arrival
type 1 signal
Frequency arrival
type 2 signal
C13, C14, C21, C22
(none)
Input
Description
State
when output to motor is at the
ON
set frequency
when output to motor is off,
or in any acceleration or
OFF
deceleration ramp
when output to motor is at or
above the set frequency the
ON
holds for, even if in acceleration
or deceleration ramps
when output to motor is off,
or during acceleration or decel-
OFF
eration before the respective
thresholds are crossed
Example:
Open collector output
CM2
50 max
DC 27Vmax
Fa1/ FA2
12
11
RY

Hide quick links: