N100 INSTRUCTION MANUAL
Terminal
Terminal name
symbol
FA1
(1)
Frequency
arrival
signal
FA2
(2)
RUN
Run signal
(0)
Overload
OL
advance
(3)
notice signal
PID control error
OD
deviation signal
(4)
AL
Alarm signal
(5)
Common
CM 2
terminal
AL 0
Alarm
AL 1
terminals
AL 2
Frequency arrival [FA1][FA2] signals is indicated
when the output frequency accelerates and
decelerates to arrive at a constant frequency.
Frequency
F01 set value
FA1
Frequency
Thresholds
C21
ON at target
frequency
When the [RUN] signal is selected, the inverter
outputs a signal on that terminal when it is in
the RUN mode.
When the output current exceeds a preset value,
the [OL] terminal signal turns on.
When the PID loop error magnitude the
preset value, the [OD] terminal signal
turns on.
The inverter alarm signal is active when a fault
has occurred.
Common terminal for intelligent output terminal
At normal status, power off(initial setting value)
At abnormal status
Contact rating : 250V AC 2.5A(resistor 1oad) 0.2A(inductor load)
30V DC 3.0A(resistor 1oad) 0.7A(inductor load)
(minimum 100V AC 10mA, 5V DC 100mA)
Description
Time
ON at
FA2
constant
frequency
C22
Time
: Al0 - AL1(closed)
: AL0 - AL2(closed)
Output terminal
specification
open-collector
output
27V DC max
50 max
C M2 12
11
RY