Multi-Speed Select [CF1][CF2][CF3][CF4]
The inverter provides storage parameters for up to 16 different target
frequencies (speeds) that the motor output uses for steady-state run
condition.
These speeds are accessible through programming four of the intelligent
terminals as binary-encoded inputs CF1 to CF4 per the table . These can be
any of the six inputs, and in any order.
You can use fewer inputs if you need eight or less speeds.
When choosing a subset of speeds to use, always start at the top of the table,
Note :
and with the least-significant bit: CF1, CF2, etc.
NOTE : Speed 0 is set by the
Multi-speed
SW5
Speed 0
OFF
Speed 1
OFF
Speed 2
OFF
Speed 3
OFF
Speed 4
OFF
Speed 5
OFF
Speed 6
OFF
Speed 7
OFF
Speed 8
ON
Speed 9
ON
Speed 10
ON
Speed 11
ON
Speed 12
ON
Speed 13
ON
Speed 14
ON
Speed 15
ON
Control circuit terminal
SW4
SW3
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
parameter value.
F 01
SW2
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON