3. N100 Inverter Standard Specifiations.
Model-specific tables for 200V and 400V class inverters
The following two tables are specific to N100 inverters for the
200V and 400V class model groups. The table on page 3-3 gives
the general specifications that apply to both voltage class groups.
Footnotes for all specifications tables are on the next page.
Item
plus
Model N100
series
Applicable motor size *2
Rated capacity(200V)kVA
Rated input voltage
Rated output voltage *3
Rated output current(A)
Starting torque
(with sensorless vector
control selected)
without resistor,
Dynamic braking
from 50/60Hz
approx. % torque,
short time stop *5
with resistor
DC braking
Weight (kg)
plus
plus
N100
N100
-007SF
-004SF
0.4
0.75
kW
HP
1/2
1
1.1
1.9
Single-phase
200 to 230V 10%,
50/60 Hz 5%
3-phase 200 to 230V (corresponding to input voltage)
3.0
5.0
Variable operating frequency, time and braking force
1.2
1.2
3-1
plus
200V Class Specifications
plus
plus
N100
N100
N100
-007LF
-015SF
-004LF
1.5
0.4
0.75
2
1/2
1
3.0
1.1
1.9
There-phase (3-wires)
200 to 230V 10%,
50/60 Hz 5%
7.0
3.0
5.0
200% or more
approximately
100%
approximately
150%
1.5
1.2
1.2
plus
plus
plus
N100
N100
N100
-037LF
-015LF
-022LF
1.5
2.2
2
3
3.0
4.2
7.0
11.0
approximately
20 40%
approximately
100%
1.5
1.5
plus
3.7
5
6.1
17.0
2.0
Need help?