Second Control Function [SET]

If you assign the [SET] function to a logic terminal, the inverter will display
the Sxx numbered parameters, allowing you to edit the second motor
parameters. These parameters store an alternate set of motor characteristic
parameters. When the terminal [SET] is turned on, the inverter will use the
second set of parameters to generate the frequency output to the motor.
When changing the state of the [SET] input terminal, first confirm the inverter
is in the Stop Mode, and the motor is not rotating.
When the switch between the set terminals [SET] and [CM1] is on, the
inverter operates per the second set of parameters.
When the terminal is turned off, the output function returns to the original
settings(first set of motor parameters.)
Terminal
Option
Symbol
Code
7
SET
Valid for inputs:
Required setting
Notes:
If the terminal is turned off while the motor
is running, the inverter continues to gener-
ate the frequency output using the 2nd set
of parameters until the motor is stopped.
Function Name
Set 2nd Motor
C01,C02,C03,C04,C05,C06
(none)
Input
State
Causes the inverter to use the 2nd
set of motor parameters for
ON
generating the frequency output to
motor
Causes the inverter to use the 1st
(main) set of motor parameters
OFF
for heating the frequency
output to motor
Example:
SET
6
CM1
Description
RV FW
5
4
3
2
1
P24