  • Page 2: Model Number Information

    HYUNDAI Inverter is, More economical for single phasing input. ▶ ▶ Adaptable, as it is possible to select various operation methods. ▶ Optimal not only at high speeds but also low speeds in its driving characteristics. Convenient for users through development of various optional products.
  • Page 3 We build a better future! P O W E R F U L O P E R A T I O N & C O M P A C T S I Z E Features Protective Functions C O N T E N T S External Dimension Diagram Terminal Functions Operation...
  • Page 4 HYUNDAI INVERTER Features Vector inverter for single phasing input only –High torque of 200% or greater at speeds as low as 1 Hz during starting and operation. Realize tripless driving by adding current suppression –Stable operation even under the instantaneous impact load and overload is realized through the addition of over-current level adjusting function.
  • Page 5: External Dimension Diagram

    HYUNDAI SINGLE PHASE VECTOR INVERTER External Dimension Diagram The N50 series inverter can be easily operated with the standard digital operator panel on the main unit. For remote operation, remote operator(DOP05) is available as an option product. External Dimension 007SF...
  • Page 6: Operation

    HYUNDAI INVERTER Operation Monitor section (LED) Power ON lamp Monitor lamp Monitor lamp Frequency setting Run key potentiometer Stop/Reset key Function key Store or Memory key Up/Down key Setting the maximum frequency Turn on Press the Display A mode Press the...
  • Page 7: General Specifications

    HYUNDAI SINGLE PHASE VECTOR INVERTER General Specifications Type Item 007SF 015SF 022SF N50-007SF N50-015SF N50-022SF Model name Applicable motor capacity (kW) 0.75 Rated output capacity (kVA) Output Rated output current (A) 10.0 Rated output voltage (V) 3-phase, 200~230 V Maximum output frequency (Hz)
  • Page 8 HYUNDAI INVERTER General Specifications Type Item 007SF 015SF 022SF Model name N50-007SF N50-015SF N50-022SF Frequency Analog 0 to 5VDC, 0 to 10VDC, 4 to 20 mA, External variable resistor (1 kΩ~2 kΩ,1 W), setting digital main unit volume resistor Input from control panel...
  • Page 9: Function List

    HYUNDAI SINGLE PHASE VECTOR INVERTER Function List Monitor Mode / Basic Setting Mode Function code Name Initial value Minimum value Maximum value Unit Code description Output frequency monitor 400.0 0.00~99.99,100.0~400.0 Hz, "Hz" LED on 0.00 Output current monitor 99.9 0.0~99.9 A display, "A" LED on...
  • Page 10 HYUNDAI INVERTER Function List Expanded Function A Mode Function code Name Initial value Minimum value Maximum value Unit Code description 0: main unit volume, 1: control terminal, Frequency commanding 2: standard operator, 3: remote operator (communication) Basic 0: standard operator, 1: control terminal,...
  • Page 11 HYUNDAI SINGLE PHASE VECTOR INVERTER Function code Name Initial value Minimum value Maximum value Unit Code description Torque boost mode selection 0: manual torque boost, 1: automatic torque boost 50.0 Manual torque boost voltage setting Manual torque boost voltage setting...
  • Page 12 HYUNDAI INVERTER Function List Expanded Function b Mode Function code Name Initial value Minimum value Maximum value Unit Code description 0: alarm output after trip 1: restart at 0 Hz 2: resume operation after frequency matching 3: resume previous frequency after...
  • Page 13 HYUNDAI SINGLE PHASE VECTOR INVERTER Expanded Function C Mode Function code Name Initial value Minimum value Maximum value Unit Code description 0: forward run command (FW) 1: reverse run command (RV) 2: 1st multispeed command (CF1) 3: 2nd multispeed command (CF2)
  • Page 14: Protective Functions

    HYUNDAI INVERTER Function List Expanded Function H Mode Function code Name Initial value Minimum value Maximum value Unit Code description O: auto-tuning OFF, 1: auto-tuning ON Auto-tuning setting Motor data setting (standard/auto-tuning) 0: standard motor constant, 1: auto-tuning data 1: 0.75 kW...
  • Page 15: Terminal Functions

    HYUNDAI SINGLE PHASE VECTOR INVERTER Terminal Functions Main Circuit Terminal Terminal symbol Terminal name Function Main power supply input terminal L1, L2 Single phase 200V class U, V, W Inverter output terminal Connect to the motor External resistor connection terminal...
  • Page 16 HYUNDAI INVERTER Application Wiring Apparatus & Option Standard Apparatus (3-Phase input reference) Wiring Applicable equipment Motor Inverter model output (kW) (N50 Series) Power lines Signal lines Fuse (class H) 10 A 0.75 N50-007SF 1.25 mm Fuse 0.14 mm 15 A...
  • Page 17 HYUNDAI SINGLE PHASE VECTOR INVERTER Option Digital Operator –Digital operator is economical remote operator. –Digital operator can control inverter parameter and operating commands. Specification Item Description Model name DOP05 External dimension 67.5 mm(H)×64.9 mm(W)×35.1 mm(D) 4-digit 7-segment LED 7-segment LED...
  • Page 18: Proper Operation

    HYUNDAI INVERTER Proper Operation –Before use, be sure to read through the Instruction Manual to insure proper operation. –Note that the inverter requires proper electrical wiring; a specialist should carry out the wiring. –The inverter in this catalog is designed for general industrial applications. For special applications in fields such as aircraft, outer space, nuclear power, electrical power, transport vehicles, clinics, and submarine relay equipment, please consult us in advance.
  • Page 19 Wiring When used with standard applicable output motors (Hyundai standard three-phase squirrel-cage four-pole motors), the N50 Series do not need a thermal relay for motor protection due to the internal electronic protective circuit. A thermal relay, however, should be used: between (a) during continuous running at a range beyond 30 to 60 Hz.
  • Page 20 Head Office 1, Jeonha-dong, Dong-gu, Ulsan, Korea Tel: 82-52-202-8101~8 Fax: 82-52-202-8100 Seoul 140-2, Gye-dong, Jongno-gu, Seoul, Korea (Sales & Marketing) Tel. 82-2-746-7596, 8451 Fax. 82-2-746-8448 Orlando 3452 Lake Lynda Drive, Suite 170, Orlando, Florida 32817, U.S.A. Tel: 1-407-249-7350 Fax: 1-407-275-4940 New Jersey 300 Sylvan Avenue, Englewood Cliffs, NJ 07632, U.S.A.

This manual is also suitable for:

Hirun n50-007sfHirun n50-015sfHirun n50-022sf

Table of Contents