SSM 6000
CONT
5.1.2
Alarm values
ALERT VALUES:
_MEAS. GASES
_TEMPERATURES
ALARM VALUES:
_CH4<
50
_O2 < 0,5
_CH4>
70
_O2 >
5
_H2S> 250
_CO2>
55
The values for CH
,, O
and CO
4
2
limit can be edited for all gas types; in the case of CH
edited.
The ex-works settings are non-binding recommendations. The manufacturer does not assume any liability for the alarm
values set! Please contact the supplier of your plant in order to identify the values to be set in order to avoid damage to
the equipment!
DEVICE INSIDE-TEMP:
_MAXWERT:
40.0
_MINWERT:
08:0
5.1.3
Single measurement
SINGLE MEASUREMENT:
_ MEASUREPOINT 1
_ START
SINGLE MEASUREMENT:
PLEASE LEAVE
SETUP
STAND-BY
Meas. with <enter>
CONT. MEASUREMENT
H2S IN
285 MIN
800C-07.07.EN
The
MEASURING GASES
be accessed via the
MEASURING PARAMETES / ALARM SETTINGS
In the
menu, separate concentration alarm thresholds can be set for each gas
ALARM VALUES
type. The alarms are made available as digital transistor outputs at the plug connector, port 2, on
the underside of the analyzer. Furthermore, the "Alarm" status LED on the display panel next to
the measured value concerned is lit up in the case of a violation of the upper or lower limit.
are expressed in percent by volume, whilst the H
2
and O
4
Additionally measures the temperature inside the device and makes this information available via
the interfaces. The
INTERNAL TEMP
transmitted via the interfaces in the case of a violation of the upper or lower limit value.
Via the SINGLE MEASUREMENT menu, a manual H
time without having to vary the measuring interval or the reference time. If the measuring-point
switch (option) is implemented, the measuring point must be selected using the <up> and <down>
keys before starting a measuring process. Press the <enter> key in order to confirm the start of
the measuring process. When prompted, operate the key switch in order to exit the setup mode.
The measuring process starts immediately. On completion of the measuring process, the current
measured values are displayed.
After the single measurement, the device is again in stand-by mode. Press the <enter> key in
order to set the device at normal measuring mode again.
The continuous measurement cycle is started. The display shows the point in time when the next
automatic H
S measurement will be performed. If the H
2
(H
S measuring interval set at = 9999), the message "H2S external start" is displayed.
2
SSM 6000C User Manual
and
menu selections for setting limit-value alarms can
TEMPERATURES
S value is expressed in ppm. Violation of an upper
2
, violation of a certain lower concentration limit can be additionally
2
menu selection enables editing of an alarm which is
2
MENU AND FUNCTION OVERVIEW
menus.
S measurement can be performed at any
S measurement is triggered externally
2
36