Removing A Dimm From The Mediation Server Module - Nortel Secure Router 4134 Installation — Hardware Components

Hide thumbs Also See for Secure Router 4134:
Table of Contents

Advertisement

11

Removing a DIMM from the Mediation Server Module

Use the procedure in this section if you must remove a DIMM from the
Mediation Server Module.
Average time to remove a DIMM from the Mediation Server Module: 3
minutes.
Prerequisites
Procedure steps
Step
1
2
3
Copyright © 2007, 2008 Nortel Networks
.
Installing or removing the DIMM on the Mediation Server Module for OCS 87
Using a Phillips screwdriver, tighten the two captive screws to
secure the module to the chassis.
Ensure the Secure Router 4134 is powered down.
Ensure you have a Phillips #2 screwdriver.
Ensure you have an antistatic bag or sheet available for the DIMM that
you are removing.
Action
Using a Phillips screwdriver, loosen the two captive screws
that secure the Mediation Server Module to the chassis. The
following figure shows the screws.
Using the lever on the module, pull the module straight out of the
chassis slot.
Support the module as you remove it from the chassis by
grasping it by the edges.
Ensure you place the Mediation Server Module on antistatic
material if you lay it down to install a DIMM.
Nortel Secure Router 4134
Installation — Hardware Components
NN47263-301 02.01 Standard
18 February 2008
--End--