ATTO Technology FastStream VT 5700 Installation And Operation Manual page 63

Fibre channel to fibre channel virtual tape appliance
Hide thumbs Also See for FastStream VT 5700:
Table of Contents

Advertisement

TapeWriteProtect
Controls write protection for a particular virtual tape or two
virtual tapes.
set TapeWriteProtect [Tape Vol ID | all] [enabled |
disabled]
get TapeWriteProtect
Temperature
Lists the current internal operating temperature of this
unit in degrees Celsius.
get Temperature
Time
Controls or lists the current time as clocked by the unit in
24 hour format. Time cannot be set if
set Time [HH: MM: SS]
get Time
TimeZone
Controls or lists the time zone or an offset from GMT for
the unit.
set TimeZone [[EST | CST | MST | PST] | [+/-HH:MM]]
Requires a SaveConfiguration command
get TimeZone
Username
Specifies the user name used for all sessions: NDMP,
Telnet, FTP and ExpressNAV. Username is case
insensitive, 1 to 32 characters, and cannot contain
spaces.
Default: root
set Username [user name]
Requires a SaveConfiguration command
get Username
VerboseMode
Controls the level of detail in CLI
command response output for the current CLI session.
Default: enabled
set VerboseMode [enabled | disabled]
get VerboseMode
SNTP
is enabled.
Help
output and
Voltage
Lists the voltage levels monitored by the FastStream.
Representations of the voltages are
VDDA: +3.31 V
VDDB: +2.49 V
VDDC: +1.5V
VDDD: +1.35V
ALL: all monitored voltages
get Voltage [VDDA |VDDB |VDDC VDDD | all]
VTLCapInfoNotify
Specifies what percentage of total storage capacity used
triggers an informational level notification is sent to the
user. The valid range is 50 percent to 75 percent.
Default:75
set VTLCapInfoNotify [percentage]
get VTLCapInfoNotify
VTLCapWarnNotify
Specifies what percentage of total storage capacity used
triggers a warning notification is sent to the user. The
valid range is 75 percent to 90 percent.
Default: 90
set VTLCapWarnNotify [percentage]
get VTLCapWarnNotify
WrapEventLog
When enabled, the FastStream logs up to 2,048 event
entries before wrapping (overwriting the first entries). If
disabled, the FastStream stops logging event entries
when the buffer is full.
Default: enabled
set WrapEventLog [enabled | disabled]
Requires a SaveConfiguration command
get WrapEventLog
zModem
Uses the zMODEM protocol to transfer a file to or from the
unit via the RS-232 port. The filename to retrieve is
required if the send option is specified.
Zmodem [send [filename] | receive]
xxii

Advertisement

Table of Contents
loading

Table of Contents