ATTO Technology FastStream VT 5700 Installation And Operation Manual page 55

Fibre channel to fibre channel virtual tape appliance
Hide thumbs Also See for FastStream VT 5700:
Table of Contents

Advertisement

DriveTestList
Specifies drives to be run in the next drive test of drives
which are not part of a RAID group or which are Hot
Spares. The all parameter automatically chooses eligible
drives. The test is not started until the
command is given.
set DriveTestList [drive [BlockDevID] | all]
get DriveTestList
DriveTestStatus
Lists the status of the currently running drive test but does
not list performance metrics. If a block device ID is not
running or cannot be found, its state is idle and percent
complete is 0.
get DriveTestStatus <drive [BlockDevID]>
DumpConfiguration
Lists the unit's configuration to a current CLI session.
DumpConfiguration
DumpEventLog
Lists the contents of the entire event log to the current CLI
session without impact on the log itself (the log is not
cleared). No events are recorded until the command has
been completed.
DumpEventLog
EmailFromAddress
Configures the Email address that the FastStream uses
to talk to the Email server. Full Email address is a fully
qualified Internet Email address, with no more than 128
characters.
set EmailFromAddress [full email address]
get EmailFromAddress
EmailNotify
Turns email notifications off and on.
Default: disabled.
set EmailNotify [enabled | disabled]
Requires a SaveConfiguration command
get EmailNotify
DriveTest
Begin
EmailNotifyAddress
Configures notification addresses using an index (a
number between 1 and 5, inclusive), the full Email
address of the recipient, a fully qualified Internet Email
address not more than 128 characters long, and a level.
Levels are
None: no Emails sent.
Critical: critical event notification.
Warning: warnings and critical event notification.
Informational: information notification
All: all warnings, critical events, informational notices
set EmailNotifyAddress [index] [full email address]
[warning level]
get EMailNotifyAddress
EmailPassword
Configures the password used to authenticate the login to
the SMTP Email server. The password must not be more
than 64 characters. A password is not required if the
Email server does not require authentication.
set EmailPassword
Requires a SaveConfiguration command
EmailServerAddress
Configures the address of the server that the FastStream
should contact in order to send Emails.
Default: 0.0.0.0
set EmailServerAddress [IP address]
Requires a SaveConfiguration command
get EmailServerAddress
EmailUsername
Configures the user name used to authenticate the login
to the SMTP Email server. The user name must not be
more than 128 characters. A user name is not required if
the Email server does not require authentication.
set EmailUsername [user name]
Requires a SaveConfiguration command
get EmailUsername
EthernetSpeed
Sets/lists the current speed of the Ethernet connection.
Choices are 10, 100, and Auto.
Default: auto
set EthernetSpeed [mp1] [ 10 | 100 | Auto ]
Requires a SaveConfiguration Restart command
get EthernetSpeed [mp1]
xiv

Advertisement

Table of Contents
loading

Table of Contents