Fibre Channel is a key technology for storage ...1 Chapter 2 ATTO FibreBridge supports diverse SAN needs ...3 Chapter 3 ATTO FibreBridge 1190E characteristics ...5 Chapter 4 How to connect SCSI devices to SCSI ports ...7 Chapter 5 How to connect the Fibre Channel port ...8 Chapter 6 ATTO FibreBridge addressing ...9...
Page 5
Examples of command usage ..iii Appendix B Standards and compliances ..vii Appendix C Fibre Channel Accessories ..ix Appendix D How to Contact ATTO Technology, Inc..xi FibreBridgeModel FirmwareRestart SerialNumber MaxEnclTempAlrm MinEnclTempAlrm ScsiPortReset...
Software stored in read-only memory (ROM) or programmable ROM (PROM). Firmware is often responsible for the behavior of a system when it is first switched 1 ATTO Technology FibreBridge 1190E Installation and Operation Manual A SAN is a shared storage architecture connecting computers and storage devices for online data access.
Page 7
Term Definition F_port A port in the Fibre Channel fabric where a N_port may attach FL-port A port in the Fibre Channel fabric where a NL_port may attach in an arbitrated loop hot swapping Components are removed and replaced while the unit is running, with power to either the component or a device connected to the unit.
Connect the FibreBridge to your SAN: attach short wave optical cables into the Fibre Channel port on the FibreBridge. (See Chapter 5) 3 ATTO Technology FibreBridge 1190E Installation and Operation Manual have the most up-to-date version of the firmware, visit the ATTO Technology website, www.attotech.com.
Page 9
Exhibit 2-1 The following chart provides an overview of the features and capabilities for the newest FibreBridge models. Contact your authorized ATTO representative or visit ATTO Technology’s website, www.attotech.com, for additional information. ATTO FibreBridge 1180E FC Ports FC port number...
3 ATTO FibreBridge 1190E characteristics The ATTO FibreBridge 1190E is a 1 x 2 (one Fibre Channel port with two SCSI ports) Fibre Channel to SCSI bridge for high throughput enterprise environments designed for mission-critical applications. The FibreBridge 1190E features a small form...
Page 11
➔ Ready: should light after power has been applied; indicates the board has completed the initialization process without any failures and is ready to handle data transfers. Exhibit 3-2 FibreBridge 1190E board layout. SCSl activity Ethernet / Serial Dual stacked Port Connector...
JBODs, RAIDs, tape, CD and DVD drives, changers, libraries and magneto optical drives. 7 ATTO Technology FibreBridge 1190E Installation and Operation Manual To connect SCSI devices to the ATTO FibreBridge: Connect a VHDCI SCSI connector from the SCSI device to a port on the FibreBridge 1190.
Arbitrated Loop. Fibre Channel technology offers a variety of cabling options including standard copper, equalized copper, multimode fiber optic, and single mode fiber optic. The FibreBridge 1190E uses an MIA compliant DB-9 or Cable length Cable type <15 meters unequalized copper ≥...
Company ID Name Format Byte Value 9 ATTO Technology FibreBridge 1190E Installation and Operation Manual The Institute of Electrical and Electronics Engineers (IEEE) assigns each manufacturer a unique Company ID. The Device ID field contains a unique value assigned by ATTO Technology to every Fibre Channel product produced by ATTO Technology.
Page 15
FibreBridge. The FibreBridge SCSI ports must be set to different SCSI IDs than the devices on the bus. SCSI devices are mapped manually to desired Fibre Channel port and Fibre Channel LUNs. Manual mapping allows you to maximize the efficiency and performance of your SCSI devices while allowing great flexibility.
Telnet. The ATTO FibreBridge should first be configured for the network using the RS-232 port to establish the correct IP address. 11 ATTO Technology FibreBridge 1190E Installation and Operation Manual through an in-band Fibre Channel link using in-band SCSI ➔ In-band SCSI over Fibre Channel ➔...
Page 17
To connect via Telnet: Supply the IP address to the Telnet program. The local echo should be set to on if the Telnet software supports it. Use Vt100 for communication. Verify that the bridge can be accessed on the local Ethernet by using the Ping utility. On most systems, type ping <IP Address>.
Screen messages, also called returns, may be either terse, with just the current information, or verbose, with labels and the current information. If you want the verbose mode, type set VerboseMode enabled. 13 ATTO Technology FibreBridge 1190E Installation and Operation Manual , also known as FibreBridge Services, ➔...
Page 19
SCSI target ID (0 <= st <= 15) Exhibit 7.1-3 POST information ATTO FibreBridge 1190 (c) 2001 ATTO Technology, Incorporated. Firmware version 003B release date Apr 30 2001, 09:47:09 Build 003B Power-On Self-Test Completion Status: GOOD 64 Megabytes of RAM Installed.
Limits: enabled or disabled Actions: set VerboseMode [enabled | disabled] 15 ATTO Technology FibreBridge 1190E Installation and Operation Manual Commands generally follow a standard format: [Get | Set] Command [Parameter 1 | Parameter 2] followed by the return or enter key.
7.1.2 Mapping commands Access to SCSI devices is via Fibre Port and Fibre LUN addresses mapped to SCSI bus, target and LUNs. The factory default mapping is shown in Appendix A. CLI commands are used to modify the mapping. The RouteXxxxx and AutoMap commands provide the mechanism to map Fibre Channel Port/LUN to SCSI bus/target/LUN.
Going Offline: RouteOffline has been issued, but queued commands are underway; becomes Offline when all queued commands are complete; new SCSI commands sent to a going offline device are rejected Action: none 17 ATTO Technology FibreBridge 1190E Installation and Operation Manual Default: enabled, or hard addressing Information: get FcHard Default: 0 <...
RouteOffline Sets a route to offline or reports its status as offline or going offline Action: set RouteOffline [fp] [fl] RouteOnline Sets a route to online or reports its status. Limits: if route is not currently mapped, command results in an error message Action: set RouteOnline [fp] [fl] Information: get RouteOffline [fp]...
Contains the ECC error statistics for the FibreBridge since the statistics were last cleared. Set form sets the statistics to zero. Limits: Maximum number of errors reported = 65535 Actions: set EccLog clear 19 ATTO Technology FibreBridge 1190E Installation and Operation Manual CLI commands are case insensitive (upper and lower case allowed anywhere).
ErrorLog Set form clears ErrorLog since previous error reported. Get form shows error messages since the report was last cleared. Actions: set ErrorLog clear Returns: Error Logs cleared IdentifyFibreBridge Enabling this option causes the Ready LED on the front panel of the FibreBridge to blink until the parameter is disabled. Actions: set IdentifyFibreBridge [enabled|disabled] SaveConfiguration LogEvent...
Action: set ScsiPortSyncTransfer [[sb [enabled | disabled] ] SaveConfiguration 21 ATTO Technology FibreBridge 1190E Installation and Operation Manual Commands generally follow a standard format: [Get | Set] Command [Parameter 1 | Parameter 2] followed by the return or enter key...
ScsiPortTaggedQueuing Specifies whether tagged command queuing is allowed on the SCSI port. Limits: [enabled | disabled] Action: set ScsiTaggedQueuing [sb [enabled|disabled]] Information: get ScsiTaggedQueuing [sb] SaveConfiguration ScsiPortUltra2 Specifies whether the selected port supports Ultra2 (LVD) transfers Limits: effective only if specified port is LVD SCSI bus Action: set ScsiPortUltra2 [sb [enabled|disabled ] ] SaveConfiguration ScsiPortWideTransfer...
Limits: applies to all Fibre Channel ports Actions: setFcFullDuplex [enabled | disabled] SaveConfiguration 23 ATTO Technology FibreBridge Installation and Operation Manual Commands generally follow a standard format: [Get | Set] Command [Parameter 1 | Parameter 2] followed by the return or enter key...
FcInitiator Allows FibreBridge to operate as an initiator on the Fibre Channel network, an attribute required for features such as Extended Copy. Actions: set FcInitiator [enabled | disabled] SaveConfiguration FcPortList Returns a list of available Fibre Channel ports and their current status. Limits: valid status values are OK and Failed Actions: none FcSCSIBusyStatus...
Limits: 1 or 2 Actions: set SerialPortStopBits [1 | 2] SaveConfiguration 25 ATTO Technology FibreBridge Installation and Operation Manual Commands generally follow a standard format: [Get | Set] Command [Parameter 1 | Parameter 2] followed by the return or enter key...
7.1.7 Ethernet configuration commands The ethernet configuration commands configure the Ethernet and TCP/IP parameters for FibreBridge models with Ethernet ports. CLI commands are case insensitive (upper and lower case allowed anywhere). EthernetSpeed Sets/displays the current speed of the Ethernet connection. Limits: [ 10 | 100 | Auto ] Actions: set EthernetSpeed xxx.xxx.xxx.xxx SaveConfiguration...
Temperature Returns the current internal temperature of the unit in degrees Celsius. Actions: none 27 ATTO Technology FibreBridge Installation and Operation Manual Commands generally follow a standard format: [Get | Set] Command [Parameter 1 | Parameter 2] followed by the return or enter key...
Zmodem Allows transfer of a firmware image to or from the FibreBridge using the ZMODEM file transfer protocol. Limits: available only through the RS232 interface WARNING After a firmware image is downloaded to the FibreBridge, the image is placed into flash memory. During this time (about 30 seconds), DO NOT remove power to the FibreBridge or the flash may become corrupted.
The initiator issues a SCSI WriteBuffer (buffer ID = 0) command to the ServicesLUN. A WriteBuffer command must be 29 ATTO Technology FibreBridge 1190E Installation and Operation Manual accompanied by an ASCII buffer representing the CLI command string such set FibreBridgeName FB1190...
Page 35
➔ Characters following the NULL character are meaningless. A CHECK_CONDITION, INVALID_PARAMETER_IN_CDB will be Exhibit 7.2-1 The SCSI command process: reserve the FibreBridge, send the command, release the FibreBridge. Initiator/Host Goal: reserve the FibreBridge for an in-band CLI command SCSI cdb: Reserve ServicesLUN Goal: retrieve the FibreBridge temperaure via in-band CLI 1.
The two most common types of Segment Descriptors are “block 31 ATTO Technology FibreBridge 1190E Installation and Operation Manual (disk) to stream (tape)” and “stream (tape) to block (drive)”. The FibreBridge supports “block to block,”...
Page 37
To enable serverless backup on the FibreBridge: Access the FibreBridge either through RS- 232 or Ethernet. After the Ready prompt, type set Fcinitiator enabled. Serverless Backup Application Server Serverless Backup Agent Serverless backup in a SAN Exhibit 8-1 Once the server sends a command to the FibreBridge for extended copy, the FibreBridge manages the backup procedure, by-passing the server.
FibreBridge until the display returns the Ready prompt. Interrupting the flash process will make your FibreBridge inoperable and you will have to return it to ATTO Technology for repair. 10 Once the download is complete, cycle power on the FibreBridge to invoke the new firmware.
Ready. get RouteOnline 0 3 ;fp fl sb st sl On/Offline 0 Online Ready. RouteDisplay 0 3 ii ATTO Technology FibreBridge 1190E Installation and Operation Manual ;fp fl sb st sl On/Offline 0 Online xx xx 0 Reserved xx xx...
Page 41
1 Online 0 Online 0 Online 4 xx xx xx 4500 5 xx xx xx Offline 6 xx xx xx Offline 0 30 xx xx xx Offline 0 31 xx xx xx Offline xx xx 0 Reserved xx xx 0 Reserved xx xx 0 Reserved xx xx...
Page 42
Setting device offline: FC 1 Lun Setting device offline: FC 2 Lun Setting device offline: FC 2 Lun iv ATTO Technology FibreBridge 1190E Installation and Operation Manual Setting device offline: FC 2 Lun Scanning SCSI bus 0 Scanning SCSI bus 1...
Page 43
Ready. RouteDisplay online ;fp fl sb st sl On/Offline 0 Online 0 Online 0 Online 3 xx xx xx 4500 0 Online 0 Online 0 Online 3 xx xx xx 4500 0 Online 0 Online 0 Online 3 xx xx xx 4500 xx xx 0 Reserved xx xx...
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Regulations. Cet appareil numerique de la classe A respecte toutes les exigences du Reglement sur le materiel brouilleur du Canada. vi ATTO Technology FibreBridge 1190E Installation and Operation Manual...
Page 45
European Standards Declaration of Conformity This following statement applies to the ATTO FibreBridge. This device has been tested in the basic operating configuration and found to be compliant with the following European Union standards: Application of Council Directive: 89/336/EEC Standard(s) to which conformity is declared: EN55022, EN50082-1 This Declaration will only be valid when this product is used in conjunction with other CE approved devices and when the entire system is tested to the applicable CE standards and found to be compliant.
Appendix C Fibre Channel Accessories The following Fibre Channel accessories are available through ATTO Technology. Contact an ATTO Technology authorized sales representative to order. Embedded FibreBridge 1180 FCBR-1180-ELC Fibre Channel to LVD Ultra2 SCSI Bridge Embedded Board with Copper DB9...
Page 47
68-pin “P” / 68-pin fine pitch “P” – 10m CBL-F68E-025 68-pin “P” / 68-pin fine pitch “P” – 25m CBL-F68E-68X 68-pin “P” / 68-pin fine pitch “P” – 16m. CBL-V68E-48 68-pin offset VHDCI to 68-pin VHDCI ix ATTO Technology FibreBridge 1190E Installation and Operation Manual...
155 CrossPoint Parkway Amherst, New York 14068 (716) 691-1999 • voice (716) 691-9353 • fax http://www.attotech.com ATTO Technology can also be reached via e-mail at the following addresses: Sales Support: Technical Support: x ATTO Technology FibreBridge 1190E Installation and Operation Manual sls@attotech.com...