You may determine the performance of drives attached to the FastStream using the ExpressNAV VTL Manager.
The following instructions assume you have already
set up at least one RAID group.
The ATTO FastStream collects various metrics to
measure performance for physical drives attached to
the FastStream during normal system operation and
drive initialization and verification.
New performance data is updated every 60 seconds
which impacts performance slightly, even if you
minimize the browser window. Exit the ExpressNAV
VTL Manager completely whenever you need
maximum performance.
You may also access drive information using SCSI
Enclosure Services (SES). Refer to
Services (SES)
on page 31.
Preliminary steps
1
If you are not already in the ExpressNAV VTL
Manager, type the IP address of your
FastStream in a standard browser. On the
splash screen, click Enter Here. In the box
Initializing and verifying drives
4
Follow the
Preliminary steps
5
Select Initialize and Verify Drives from the
Select User Process menu.
6
Click Next.
7
If no drives appear in the information box, click
System Scan .
If drives are available, select the drives you
wish to verify, initialize or test. The drives are
highlighted.
8
Click Commit .
21
ATTO Technology Inc. FastStream SC Installation and Operation Manual
6.2 Drive Diagnostics
2
3
SCSI Enclosure
above.
9
10 The Health and Status Monitor page appears.
provided , type in your user name and
password, and click OK .
The Monitor VTL page appears. Click
Diagnostics on the left menu.
Select the operation you wish to perform from
the Select User Process menu.
CAUTION
CAUTION
Do not restart the FastStream or
disconnect or power cycle drives during
Drive Initialization and Verification or you
must start the verification process from the
beginning.
A warning box appears. In the warning box,
verify that you want to complete the
configuration by selecting Yes . Selecting No
ends the procedure without making a change.
All data on the previously-highlighted drives
has been erased.