RGWaitTimeout
Specifies the maximum time in seconds that the system
waits to discover previously-configured RAID groups
attached to the drive. The timeout is used during system
boot time and when the
BlockDevScan
issued.
Default: 5
set RGWaitTimeout [1-3600]
Requires a SaveConfiguration Restart command
get RGWaitTimeout
RMStatus
Lists the status of all RAID members within the specified
RAID group or a specific RAID member (if specified)
within a RAID group.
RMStatus [GroupName] <Member Index>
Route
Assigns a host protocol address to a target destination
device. More than one FC LUN may be assigned to a
partition. If you try to map a new partition to the same FC
LUN, the previous map is overwritten.Use the Delete
identifier to remove the map. In verbose mode,
overwriting a map requires secondary confirmation of the
action.
Route [FC] [fp] [lun] [ [RAID [GroupName] [Partition
Index]] [ Bridge | Delete ]
RouteDisplay
Lists a combined list of host protocol address to target
destination device mappings.
RouteDisplay FC <fp> <lun>
SaveConfiguration
Issued with the restart option, cycles unit power after
saving configuration changes. The norestart option
saves changes without restarting.
Note
Certain modifications require a system restart.
SaveConfiguration <Restart | NoRestart>
SerialNumber
Reports the FastStream serial number which is unique for
each FastStream. The serial number tracks the board
throughout its life and should not be changed.
get SerialNumber
SerialPortBaudRate
Configures the baud rate for the unit's RS-232 serial port.
The number of data bits is fixed at 8 with no parity.
Default: 115200
command is
set SerialPortBaudRate [ 9600 | 19200 | 38400 | 57600 |
115200]
Requires a SaveConfiguration Restart command
get SerialPortBaudRate
SerialPortEcho
Controls if the unit echoes characters on its RS-232 port.
When enabled, all non-control character keyboard input
is output to the screen.
Default: enabled
set SerialPortEcho [enabled | disabled]
get SerialPortEcho
SES
Enables support for SES enclosures that have been
discovered by the appliance.
Default: enabled
set SES [enabled | disabled]
get SES
SESAlarmTest
Turns on the specified enclosure's audible alarm at the
specified warning level. Reset turns off the alarm.
SESAlarmTest [EnclosureIndex] [SET | RESET] [INFO |
NON-CRIT | CRIT | UNRECOV]
SESDiskFailureAlarm
Activates an audible alarm when the appliance
determines that a RAID member disk drive has failed.
The enclosure which contains the failed disk drive creates
the sound, other enclosures are unaffected.
Default: disabled
set SESDiskFailureAlarm [enabled | disabled]
get SESDiskFailureAlarm
SESEnclosures
List SES-enabled enclosures which have been
discovered by the appliance.
SESEnclosures
Note
The SESEnclosures command must be
executed before executing