Metrics
Controls the collection of standard data metrics within a
product via the command's Start, Stop and Display
parameters.
Metrics [Start | Stop | Display| Clear] [drive [BlockDevID] |
all | running]
MinOpTemp
Regulates the minimum operating temperature of this unit
in degrees Celsius. Valid entries are between 0
°
15
C.
Default: 0
set MinOpTemp [0 – 15]
Requires a SaveConfiguration Restart command
get MinOpTemp
OpTempWarn
Regulates the number of degrees Celsius before a
thermal control event precipitates a warning to the user.
Valid entries are between 0
Default: 0
set OpTempWarn [0 – 15]
Requires a SaveConfiguration Restart command
get OpTempWarn
PartitionDisplay
Lists all the partitions available in the specified RAID
group. The partitions are listed in order of contiguousness
(as opposed to index order).
PartitionDisplay [GroupName]
PartitionWriteCache
If enabled, allows higher write performance with a small
risk of data loss after a system failure. If disabled,
provides a higher level of data integrity with lower write
performance.
set PartitionWriteCache [GroupName] {PartIndex]
[enabled | disabled]
get PartitionWriteCache [GroupName] {PartIndex]
PassThroughMode
Specifies the non-disk device types which are
automatically mapped at boot time. The all option allows
all non-disk devices to be mapped. The SES option
allows dedicated SES processor LUNs to be mapped.
The non-SES option allows all non-SES devices to be
mapped. The disabled option disables the pass-through
mode.
Default: disabled
set PassThroughMode [all | SES |non-SES | disabled]
get PassThroughMode
xvii
ATTO Technology, Inc. FastStream VT Installation and Operation Manual
°
C and
°
°
C and 15
C.
PassThroughPersistent
Stores maps for currently-attached passthrough devices
to persistent memory,
PassThroughPersistent
PassThroughRediscover
Makes any previously-deleted pass through target
devices visible to the host.
PassThroughRediscover
Password
Specifies password for all non-serial sessions: Telnet, ftp
and FastStream browser-based user interface. You are
prompted for the current password, to type the new
password, and to confirm the new password. If local
echo is enabled, password echoes all * characters. In
verbose mode only, CLI requests the password be re-
typed. When the password is all 0s, Telnet and ftp do not
validate the password and MD5 authentication is
disabled. Passwords are case sensitive and can be 1-32
characters long with no spaces.
Default: Password
set Password
Requires a SaveConfiguration command
Performance
Returns the performance data for the FC port you specify.
Data includes the average rate (MB per sec.) and number
of I/Os measured over the previous sampling period
where a sampling period is approximately one second.
Successful SCSI Read (08h, 28h) and Write (Oah, 2Ah)
commands are considered I/Os.Reported performance
may be affected by FC port availability and saturation,
device speeds and overall system use.
get Performance <fp>
Ping
Sends an ICMP echo request to the specified host.
ping [mp1] [xxx.xxx.xxx.xxx] <count <size>>
RAIDRebuildPriority
Sets or lists the RAID rebuild priority. A RAID rebuild
priority set to high gives higher priority to RAID rebuilds
and lower priority to the processing of simultaneous I/O
transactions. A RAID rebuild priority set to low gives
lower priority to the rebuild and a higher priority to I/O
transactions. Set same, the RAID rebuild and
processing of I/O transactions is the same.
Default: same
set RAIDRebuildPriority [high | low | same]
Requires a SaveConfiguration command
get RAIDRebuildPriority