6-254 Minutes: Enter a value between 6 and 254 minutes.
»
255: To transmit a cancellation report anytime the system is disarmed after an alarm, enter 255.
Q205: Alarm abort window transmission delay
Configures the amount of time the system will wait to initiate the digital transmission when an alarm condition is triggered. This setting specifies
the number of seconds the user has to manually abort the alarm, in the event of a false alarm.
NOTE: The transmission delay can be increased to 45 seconds without affecting ANSI/SIA CP-01 compliance only if the combination of
Q205 and Q202: Entry delay 1, in seconds (30-240) in Q203: Entry delay 2, in seconds (30- 240) does not exceed one (1) minute.
Choose one of these options:
»
15 seconds: The system waits 15 seconds to initiate the dialer.
»
† ‡ 30 seconds: For compliance with ANSI/SIA CP-01-2010, the default minimum setting is 30 seconds. This setting can be increased
to 45 seconds without affecting compliance only if the combination of this setting.
»
45 seconds: The system waits 45 seconds to initiate the dialer.
Q206: Burglary bell cutoff time
Defines the amount of time the system sounds the burglary alarm after the alarm is activated. After the time set here expires, the alarm siren
shuts OFF.
NOTE: This setting only affects the 2GIG EDGE Panel alarm. It does not affect any auxiliary alarms that may be installed. Typically,
auxiliary alarms are set to sound for an unlimited amount of time.
Choose one of these options:
»
† 4 Minutes: The alarm siren shuts OFF after 4 minutes.
»
8 Minutes: The alarm siren shuts OFF after 8 minutes.
»
12 Minutes: The alarm siren shuts OFF after 12 minutes.
»
16 Minutes: The alarm siren shuts OFF after 16 minutes.
»
Unlimited Time: The alarm siren must be shut OFF manually.
Q207: Fire bell cutoff time
Specifies the amount of time a Carbon Monoxide Detector or Smoke/Heat/Freeze Alarm should sound after the alarm is activated. After the time
set here expires, the alarm siren shuts OFF.
NOTE: This setting only affects the 2GIG EDGE Panel alarm. It does not affect any auxiliary alarms that may be installed. Typically,
auxiliary alarms are set to sound for an unlimited amount of time.
Choose one of these options:
»
† 4 Minutes: The alarm siren shuts OFF after 4 minutes.
»
8 Minutes: The alarm siren shuts OFF after 8 minutes.
»
12 Minutes: The alarm siren shuts OFF after 12 minutes.
»
16 Minutes: The alarm siren shuts OFF after 16 minutes.
»
Unlimited Time: The alarm siren must be shut OFF manually.
Q208: Swinger shutdown count
Specifies the swinger shutdown count for burglary protection zones. This defines the maximum number of times a zone's sensor can activate (i.e.,
"trip") an alarm during a single arming session. For example, if the count is set to two (2) trips, a window contact sensor would be permitted to
trip the alarm a maximum of two (2) times during a single arming session.
Choose one of these options:
»
1-6 Trips: Use the touchscreen's numeric keypad to specify a value between one (1) and six (6) trips.
»
† ‡ 2 Trips: For compliance with ANSI/SIA CP-01-2010, this is the default setting.
Q209: Cross sensor timeout, in seconds
Defines the maximum number of seconds it takes the system to activate an alarm when both sensors in a cross sensor zone are violated. The
value you define here specifies the maximum amount of time that can pass between the violation of sensors programmed for Wireless Zone 99
and Wireless Zone 100. If both sensors are violated within the amount of time specified here, the system activates an alarm. If only one of the
sensors is violated during the timeout interval, the system transmits a trouble report to the Central Station and does not activate an alarm.
NOTE: For the timeout to affect the system, the Cross Sensor Zones feature must also be enabled on the system. See Q123: Cross
sensor zones 99-100.
You have these options:
2GIG EDGE Installation Guide
48
»
† 10 Seconds: Defines the cross sensor time interval as 10 seconds.
»
1- 120 Seconds: To extend the timeout interval, the installer programs a value between 1 to 120 seconds.
Q210: Time to detect AC loss, in minutes
Configures the system to display a trouble alert in response to AC power loss after a specified amount of time has passed. By default, the system
is configured to both display and sound a trouble alert when the 2GIG EDGE Panel is without AC power for 10 minutes. When AC power is restored
to the 2GIG EDGE Panel, the trouble alert condition clears automatically after one (1) minute.
Choose one of these options
»
0 Minutes: Turns the feature OFF.
»
† 10 Minutes: The system displays a trouble alert on the touchscreen and sounds a trouble siren when the 2GIG EDGE Panel is without
AC power for 10 minutes.
»
1-30 Minutes: Enter a value between one (1) and 30 minutes
NOTE: The Time to Detect AC Loss feature also transmits a trouble report to the Central Station. The time at which the trouble report is
sent depends on what the installer configured for Q211: Random AC loss report time below.
Q211: Random AC loss report time
Configures the 2GIG EDGE Panel to transmit the Central Station a trouble report about AC power loss. When enabled, the system transmits the report
at a random time that falls within 45 minutes of the time at which the Time to Detect AC Loss, in Minutes feature was first triggered. See
on the previous page. When enabled, this feature minimizes network congestion for the Central Station, should a regional area
detect AC loss, in minutes
experiencing a widespread power outage affect a large number of 2GIG EDGE Panel users.
Choose one of these options:
»
† Enabled: Turns the feature ON.
»
Disabled: Turns the feature OFF.
Q212: Siren supervision time
Configures the system to supervise the wire between an external alarm sounder (if installed) and the 2GIG EDGE Panel. In the event that the
supervised wire is cut, the system waits the number of seconds specified here and then displays a trouble alert on the 2GIG EDGE Panel's
touchscreen. It also transmits a trouble report to the Central Station.
Choose one of these options:
»
† Disabled: Turns the feature OFF.
»
15 Seconds: Turns the feature ON. 15 seconds after a wire cut is detected, the system displays a trouble alert on the touchscreen and
also transmits a trouble report to the Central Station.
»
30 Seconds: Turns the feature ON. 30 seconds after a wire cut is detected, the system displays a trouble alert on the touchscreen and
also transmits a trouble report to the Central Station.
»
45 Seconds: Turns the feature ON. 45 seconds after a wire cut is detected, the system displays a trouble alert on the touchscreen and
also transmits a trouble report to the Central Station.
Panel Configurations
Q301: Police emergency key
Configures the system to respond in two (2) ways when a user manually activates a panic alarm on the 2GIG EDGE Panel. The system can either
be set to emit a loud, patterned warning siren or to set off a silent panic alarm with no siren. You can also disable the Panic button so that it is not
visible on the 2GIG EDGE Panel.
Choose one of these options:
»
Disabled: Turns the feature OFF and hides the Panic button from the Alarm screen.
»
† Audible: Turns the feature ON. This makes the Panic button visible on the Alarm screen. The system sounds a loud, patterned warning
siren after the user activates a panic alarm.
»
Silent Panic: Turns the feature ON. This makes the Panic button visible on the Alarm screen. The system sounds a silent panic alarm
with no warning siren after the user activates a panic alarm.
Q302: Fire emergency key
Configures the system to show or hide the Fire button on the Alarm screen of the 2GIG EDGE Panel's touchscreen. When set to Audible, the button is
visible and the system emits a loud, patterned warning siren when a user manually activates a fire emergency alarm on the 2GIG EDGE Panel.
Choose one of these options:
»
Disabled: Turns the feature OFF and hides the Fire button from the Alarm screen.
Q210: Time to