2gig Technologies EDGE Installation Manual page 23

Security & smart home system
Hide thumbs Also See for EDGE:
Table of Contents

Advertisement

»
Disabled: Disable 2-way voice.
»
† Stay on line: Default. 2-way voice is enabled.
»
Stay on line, incl fire & CO alarms: 2-way voice is enabled and includes fire and CO alarms.
Q106: Disable siren after two-way audio
Configures the system to automatically turn the alarm siren ON or OFF after the end of a 2-Way Voice session. For this setting to take effect,
"Q105: 2-way voice" above must be enabled.
Choose one of these options:
»
Enabled: Choose this setting if you want the alarm siren to remain OFF after a 2-Way Voice session ends.
»
† Disabled: Choose this setting if you want the alarm siren to resume after a 2-Way Voice session ends.
NOTE: When set to disabled, the alarm siren will only resume after a 2-way voice session when the corresponding alarm bell cutoff time
has not expired. See
and
Q206: Burglary bell cutoff time
Q207: Fire bell cutoff time
Q107: Smart Areas
Configures "Smart Areas" (partitioning) feature allowing the system to be divided into four separate areas. Once enabled, zones, keyfobs, keypads,
and users can be assigned to Smart Areas allowing individual control of each area.
Choose one of these options:
»
Enabled: Smart Areas button will be displayed on 2GIG EDGE Panel and all 2GIG EDGE Remote keypads. Zones, Keyfobs, Keypads can
be assigned to a single Smart Area. Users can be assigned and control assigned Smart Areas. Smart Areas Settings will allow naming of
all four areas.
»
† Disabled: Smart Areas button will not be displayed on the home screen of the 2GIG EDGE and Remote Keypads. Smart Areas
Settings will only display the main system.
NOTE: Programming of Zones, Keyfobs, and Keypads is not restricted and all devices can be programmed and assigned to any of the
four Smart Areas but will be inactive if assigned to Smart Area 2-4 until this feature is enabled.
Q108: Z-Wave feature
Configures the system to show or hide the Smart Home Controls button on Home screen of the touchscreen. When this feature is enabled, it
provides users with access to the smart devices on the network.
Choose one of these options:
»
Disabled and Hidden: Hides the Smart Home Controls button on the Home screen.
»
Disabled but Visible: Shows the Smart Home Controls button on the Home screen. When a user taps the button, the This feature is
not currently activated message displays.
»
† Enabled: Shows the Smart Home Controls button on the Home screen. Users can operate smart devices from the touchscreen or
remotely.
Q109: Master user can access Z-Wave setup
Configures the system to allow persons who know the system's Master User Code to gain access to the System Settings > Smart Home Settings menu.
Choose one of these options:
»
Enabled: This makes the Smart Home Settings button available in the System Settings menu after entering the Master User Code.
»
† Disabled: This grays out the Smart Home Settings button and makes it unavailable in the System Settings menu.
Q110: Smart Home Controls require master code
Configures the system to prompt the user for the master code when attempting to access the Smart Home Controls menu (if enabled). See
Z-Wave feature
above.
Choose one of these options:
»
Enabled: When a user taps the Smart Home Controls button, the Enter Your Code to Access Smart Home
»
Controls screen appears.
»
† Disabled: Opens the Smart Home Controls menu, without prompting the user for a code.
Q111: Main Panel Sounder Follows
Configures the system to allow alarms in all Smart Areas to sound the Main panel.
Choose one of these options:
»
† All Smart Areas: Alarms from any Smart Area will alert and sound at the 2GIG EDGE Panel.
»
Main Panel Smart Area Only: Only alarms in Smart Area 1 will alert at the 2GIG EDGE Panel, alarms in Smart Areas 2-4 will only
alert on keypads assigned to those areas.
NOTE: With both options alarms for all Smart Areas are visible by entering the Smart Areas Screen via the Home Screen button.
2GIG EDGE Installation Guide
.
44
Q112: Z-Wave siren mode
Configures the system to sound any Z-Wave sirens that have been added to the network.
Choose one of the options:
»
† Sound for Burglary and Fire/CO: Configures the system to sound any connected Z-Wave sirens during a burglary, fire, or CO
alarm.
»
Sound for Burglary Only: Configures the system to sound any connected Z-Wave sirens during burglary alarms only.
Q113: Quick arming
Turns the system's quick arming feature ON and OFF. This feature can be assigned individually for each Smart Area. (Smart Areas feature must
be enabled (Q107) for settings for S2-S4 to affect the system) When ON, any occupant can arm the system. When OFF, only persons who know an
active user code can arm the system.
Choose one of these options:
»
† Enabled: Turns the feature ON and does not require occupants to enter a user code to arm the system.
»
Disabled: Turns the feature OFF and requires occupants to enter an active, user code or Face Recognition (if enabled) to arm the
system.
Q114: Auto stay
Turns the system's Auto Stay feature ON and OFF. This feature can be assigned individually for each Smart Area. (Smart Areas feature must be
enabled (Q107) for settings for S2-S4 to affect the system) When ON, the system monitors the Exit Delay doors after the user arms the system in
Away Mode at the 2GIG EDGE Panel. If no one exits that door before the Exit Delay countdown expires, the system automatically arms itself in Stay
Mode.
See Q201: Exit delay
, in seconds (45-120). This setting does not go into effect when arming the system in Away Mode with a keyfob or from
Alarm.com.
Choose one of these options:
»
Disabled: Turns the feature OFF. The system arms itself in Away Mode at the end of the Exit Delay countdown.
»
† ‡ Enabled: Turns the feature ON. The system monitors the Exit Delay door when the system is armed and if no one exits the door
before the Exit Delay countdown expires, the system automatically arms the system in Stay Mode. For compliance with ANSI/SIA CP-01-
2010, this feature is enabled by default.
Q115: Exit delay restart
Configures the system to restart the Exit Delay countdown if a user must re-enter the premises through an Exit Delay door during the initial Exit
Delay countdown. This feature can be assigned individually for each Smart Area. (Smart Areas feature must be enabled (Q107) for settings for S2-
S4 to affect the system) This is useful when a user arms the system, exits the premises, and then needs to quickly enter/exit the premises before
the countdown expires. As long as the user exits the premises during the Exit Delay Restart countdown, there is no need to disarm and re-arm the
system. When this feature is turned ON, the Exit Delay timer will restart one (1) time.
Choose one of these options:
»
† ‡ Enabled: Turns the feature ON. If the user exits and then re-enters the premises before the Exit Delay countdown expires, the Exit
Delay countdown restarts before the system is armed. For compliance with ANSI/SIA CP-01-2010, this feature is enabled by default
»
Disabled: Turns the feature OFF.
NOTE: When the Exit Delay Restart feature is enabled on the system and the user arms the system with the Silent Exit feature enabled,
the system will restart the exit countdown using the Silent Exit timer, instead of the Exit Delay timer.
NOTE: When the Exit Delay Restart feature is enabled on the system and the user triggers the Exit Delay Restart feature, the Quick Exit
button is disabled.
Q108:
Q116: Allow quick exit
Configures the system to allow users to quickly exit the premises while the system is armed in Stay Mode. When this feature is turned ON and
a user taps Arm Stay, a Quick Exit button appears on the System Armed screen. When a user taps Quick Exit , the system starts the Exit Delay
countdown and the user must exit the premises before the countdown expires. After the countdown expires, the system automatically re-arms
itself in the specified arming mode.
Choose one of these options:
»
† Enabled: Turns the feature ON. This enables the Quick Exit button on the System Armed screen.
»
Disabled: Turns the feature OFF.
NOTE: The Quick Exit button is not available on the System Armed screen when the user invokes the Exit Delay Restart feature. See
Q115: Exit delay restart
.